Noninvasive detection and monitoring of multiple myeloma by urinary surface-enhanced raman spectroscopy and machine learning

Abstract Abstract Background: Multiple myeloma (MM) is the second most common hematologic malignancy, characterized by high relapse rates and a lack of curative therapies. MM's diagnosis and treatment-efficacy monitoring is still depend on invasive bone-marrow biopsy, immunofixation electrophoresis, and imaging studies now. These methods are time-consuming and lack sensitivity in early disease stages. Urinary surface-enhanced Raman spectroscopy (SERS) combined with machine learning offers a rapid, non-invasive approach for biomarker detection. Objective:To evaluate the feasibility and diagnostic performance of non-invasive detection of MM using urinary SERS combined with a principal component analysis–random forest (PCA–RF) model. Methods: The study was approved by the Ethics Committee of China–Japan Union Hospital of Jilin University (approval No.: 2025-KYYS-036). This single-center, retrospective study in the Department of Hematology recruited 13 patients with newly diagnosed MM and 13 healthy volunteers matched for age and sex. First-morning midstream urine samples were collected upon admission after ≥12 h fasting and prior to any treatment. Each 200 µL sample was mixed with 40 µL silver nanoparticle solution and analyzed on an ATR3100 Raman spectrometer (785 nm, 100 mW), acquiring 100 spectra per subject (3-scan average; total n = 2600). Spectra were baseline-corrected, normalized, then dimensionally reduced via PCA to the top 50 principal components, and finally classified using a random forest model. Receiver operating characteristic (ROC) area under the curve (AUC), accuracy, sensitivity, and specificity were assessed by five-fold cross-validation. Results:The PCA–RF model achieved a mean AUC of 0.975. Five-fold cross-validation yielded an average accuracy of 90.85%, sensitivity of 91.40%, and specificity of 90.30%. Calibration curves demonstrated excellent agreement between predicted probabilities and observed incidences. The primary discriminative peaks were located at approximately 600 cm⁻¹ (aromatic amino acid vibrations) and 1500 cm⁻¹ (nucleoside metabolite vibrations). Conclusions:Urinary SERS combined with the PCA–RF model enables highly accurate, non-invasive detection and monitoring of MM. Its rapid analysis, strong reproducibility, and excellent patient compliance make it well suited for outpatient and bedside use. Future work will involve prospective, multicenter validation and the integration of metabolomic profiles with standard clinical parameters to refine the model and advance its clinical translation. Keywords: multiple myeloma; non-invasive detection; surface-enhanced Raman spectroscopy (SERS); machine learning; random forest; silver nanoparticles

Authors

Institutions

Publication Details

Journal
Blood
Published
2025-11-03
DOI
https://doi.org/10.1182/blood-2025-7876
Primary Topic
Spectroscopy Techniques in Biomedical and Chemical Research
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Noninvasive detection and monitoring of multiple myeloma by urinary surface-enhanced raman spectroscopy and machine learning

Yunjie Wang, Xinran Zhu, Lintao Bi, Jingxin Liu et al.
Blood
Spectroscopy Techniques in Biomedical and Chemical Research
article

Noninvasive detection and monitoring of multiple myeloma by urinary surface-enhanced raman spectroscopy and machine learning

Yunjie Wang, Xinran Zhu, Lintao Bi, Jingxin Liu, Di Zhou
article en

Abstract

Abstract Abstract Background: Multiple myeloma (MM) is the second most common hematologic malignancy, characterized by high relapse rates and a lack of curative therapies. MM's diagnosis and treatment-efficacy monitoring is still depend on invasive bone-marrow biopsy, immunofixation electrophoresis, and imaging studies now. These methods are time-consuming and lack sensitivity in early disease stages. Urinary surface-enhanced Raman spectroscopy (SERS) combined with machine learning offers a rapid, non-invasive approach for biomarker detection. Objective:To evaluate the feasibility and diagnostic performance of non-invasive detection of MM using urinary SERS combined with a principal component analysis–random forest (PCA–RF) model. Methods: The study was approved by the Ethics Committee of China–Japan Union Hospital of Jilin University (approval No.: 2025-KYYS-036). This single-center, retrospective study in the Department of Hematology recruited 13 patients with newly diagnosed MM and 13 healthy volunteers matched for age and sex. First-morning midstream urine samples were collected upon admission after ≥12 h fasting and prior to any treatment. Each 200 µL sample was mixed with 40 µL silver nanoparticle solution and analyzed on an ATR3100 Raman spectrometer (785 nm, 100 mW), acquiring 100 spectra per subject (3-scan average; total n = 2600). Spectra were baseline-corrected, normalized, then dimensionally reduced via PCA to the top 50 principal components, and finally classified using a random forest model. Receiver operating characteristic (ROC) area under the curve (AUC), accuracy, sensitivity, and specificity were assessed by five-fold cross-validation. Results:The PCA–RF model achieved a mean AUC of 0.975. Five-fold cross-validation yielded an average accuracy of 90.85%, sensitivity of 91.40%, and specificity of 90.30%. Calibration curves demonstrated excellent agreement between predicted probabilities and observed incidences. The primary discriminative peaks were located at approximately 600 cm⁻¹ (aromatic amino acid vibrations) and 1500 cm⁻¹ (nucleoside metabolite vibrations). Conclusions:Urinary SERS combined with the PCA–RF model enables highly accurate, non-invasive detection and monitoring of MM. Its rapid analysis, strong reproducibility, and excellent patient compliance make it well suited for outpatient and bedside use. Future work will involve prospective, multicenter validation and the integration of metabolomic profiles with standard clinical parameters to refine the model and advance its clinical translation. Keywords: multiple myeloma; non-invasive detection; surface-enhanced Raman spectroscopy (SERS); machine learning; random forest; silver nanoparticles

BloodVol. 146(Supplement 1)
Union Hospital (HK), Jilin University (CN)
Openalex Percentile: Top 74%
Spectroscopy Techniques in Biomedical and Chemical Research
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.