Limitations of multiexponential T1 mapping of cortical myeloarchitecture

Neuropsychiatric malignancies frequently manifest at the level of individual cortical layers. The resolutions currently available for medical magnetic resonance imaging (MRI) prevent the study of these pathologies at clinically available field strengths of 3 T. Previous studies have claimed to have overcome these issues by extensions of quantitative MRI. Following this, the feasibility of multiexponential T1 relaxometry was assessed as a basis for in vivo delineation of cortical lamination. Three methods of non-linear least-squares-based multiexponential analysis were examined across key degrees of freedom identified in the literature. The methods employ a wide variety of ways to overcome the common pitfalls of multiexponential analysis, such as regularization, bound constraints, and repeated optimization from multiple starting points. A custom MRI phantom was 3D-printed and filled with various MnCL2 mixtures that represent the spin-lattice relaxation times that commonly occur in neocortical gray and white matter at 3 T. A 96 × 96-voxel image consisting of a single slice was acquired using a FLASH sequence and used to create 10 composite datasets with known distributions of T1 decay constants. The results showed that lowest relative error achieved across multiexponential models was approximately 20%. As achieving even this level of estimation accuracy requires either T1 ratios that rarely occur in the cerebral cortex or knowledge of the number of relaxation components and their expected values to a degree that is seldom feasible, the visualization of cortical layers based on these estimates is unlikely to represent their true distribution. In conclusion, the current methodological approaches do not allow for sufficiently precise estimation of T1 decay constants spanning the range of cortical gray and white matter.

Authors

Institutions

Publication Details

Journal
PLoS ONE
Published
2025-12-04
DOI
https://doi.org/10.1371/journal.pone.0338035
Primary Topic
Advanced MRI Techniques and Applications
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Limitations of multiexponential T1 mapping of cortical myeloarchitecture

Daniel Schwarz, Jiří Vitouš, Radovan Jiřík, Jakub Jamárik et al.
PLoS ONE
Advanced MRI Techniques and Applications
article

Limitations of multiexponential T1 mapping of cortical myeloarchitecture

Daniel Schwarz, Jiří Vitouš, Radovan Jiřík, Jakub Jamárik, Eva Koriťáková
article en

Abstract

Neuropsychiatric malignancies frequently manifest at the level of individual cortical layers. The resolutions currently available for medical magnetic resonance imaging (MRI) prevent the study of these pathologies at clinically available field strengths of 3 T. Previous studies have claimed to have overcome these issues by extensions of quantitative MRI. Following this, the feasibility of multiexponential T1 relaxometry was assessed as a basis for in vivo delineation of cortical lamination. Three methods of non-linear least-squares-based multiexponential analysis were examined across key degrees of freedom identified in the literature. The methods employ a wide variety of ways to overcome the common pitfalls of multiexponential analysis, such as regularization, bound constraints, and repeated optimization from multiple starting points. A custom MRI phantom was 3D-printed and filled with various MnCL2 mixtures that represent the spin-lattice relaxation times that commonly occur in neocortical gray and white matter at 3 T. A 96 × 96-voxel image consisting of a single slice was acquired using a FLASH sequence and used to create 10 composite datasets with known distributions of T1 decay constants. The results showed that lowest relative error achieved across multiexponential models was approximately 20%. As achieving even this level of estimation accuracy requires either T1 ratios that rarely occur in the cerebral cortex or knowledge of the number of relaxation components and their expected values to a degree that is seldom feasible, the visualization of cortical layers based on these estimates is unlikely to represent their true distribution. In conclusion, the current methodological approaches do not allow for sufficiently precise estimation of T1 decay constants spanning the range of cortical gray and white matter.

PLoS ONEVol. 20(12)
Masaryk University (CZ), Czech Academy of Sciences, Institute of Scientific Instruments (CZ), Brno University of Technology (CZ)
Openalex Percentile: Top 47%
Advanced MRI Techniques and Applications
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.