A Turn-On Fluorescent and Ratiometric Electrochemical Dual-Mode Probe for Hydrogen Peroxide Detection in Brain Microdialysates of Alzheimer’s Disease Mice

Hydrogen peroxide (H<sub>2</sub>O<sub>2</sub>), a pivotal reactive oxygen species (ROS), is closely linked to oxidative stress in the pathogenesis of Alzheimer's disease (AD). Herein, we report a dual-mode probe (Re-PS) integrating turn-on fluorescence and ratiometric electrochemistry for the selective detection of H<sub>2</sub>O<sub>2</sub> in brain microdialysates of AD model mice. The probe is constructed using resorufin (Re) as a dual-signal reporter and a pentafluorobenzenesulfonyl (PS) group as the H<sub>2</sub>O<sub>2</sub>-responsive unit. Upon reaction with H<sub>2</sub>O<sub>2</sub>, the PS group undergoes nucleophilic substitution, leading to the release of Re; this process triggers a fluorescence "turn-on" response and generates a ratiometric electrochemical signal. Compared with ester-based probes, Re-PS shows superior stability due to the strong electron-withdrawing effect of fluorine atoms in the PS group. The fluorescence mode achieves a detection limit (LOD) of 50 nM, while the electrochemical detection mode (using a carbon fiber microelectrode modified with carbon nanotubes (CFME/CNT)) has a detection range of 1.0-50 μM. Both modes exhibit excellent selectivity against other ROS and biomolecules. In vivo microdialysis analysis reveals significantly elevated H<sub>2</sub>O<sub>2</sub> levels in the brains of AD mice (28.6 ± 3.2 μM) compared with wild-type mice (10.3 ± 1.8 μM). This dual-mode strategy enables cross-validation, providing a reliable tool for monitoring oxidative stress in neurodegenerative diseases.

Authors

Institutions

Publication Details

Journal
Analytical Chemistry
Published
2025-12-04
DOI
https://doi.org/10.1021/acs.analchem.5c05358
Citations
3
Primary Topic
Electrochemical sensors and biosensors
Type
article
Field-Weighted Citation Impact
2.19
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

A Turn-On Fluorescent and Ratiometric Electrochemical Dual-Mode Probe for Hydrogen Peroxide Detection in Brain Microdialysates of Alzheimer’s Disease Mice

Yintang Zhang, Menghao Cheng, Weitian Chen, Hui Dong et al.
3 citations
Analytical Chemistry
Electrochemical sensors and biosensors
2.19
article

A Turn-On Fluorescent and Ratiometric Electrochemical Dual-Mode Probe for Hydrogen Peroxide Detection in Brain Microdialysates of Alzheimer’s Disease Mice

Yintang Zhang, Menghao Cheng, Weitian Chen, Hui Dong, Yitong Jiang, Yanwen Zhou, Yanli Zhou, Maotian Xu, Tao Wang, Aixin Chang, Zhaohui Li, Xiaoyu Lv
article en
3 citations

Abstract

Hydrogen peroxide (H<sub>2</sub>O<sub>2</sub>), a pivotal reactive oxygen species (ROS), is closely linked to oxidative stress in the pathogenesis of Alzheimer's disease (AD). Herein, we report a dual-mode probe (Re-PS) integrating turn-on fluorescence and ratiometric electrochemistry for the selective detection of H<sub>2</sub>O<sub>2</sub> in brain microdialysates of AD model mice. The probe is constructed using resorufin (Re) as a dual-signal reporter and a pentafluorobenzenesulfonyl (PS) group as the H<sub>2</sub>O<sub>2</sub>-responsive unit. Upon reaction with H<sub>2</sub>O<sub>2</sub>, the PS group undergoes nucleophilic substitution, leading to the release of Re; this process triggers a fluorescence "turn-on" response and generates a ratiometric electrochemical signal. Compared with ester-based probes, Re-PS shows superior stability due to the strong electron-withdrawing effect of fluorine atoms in the PS group. The fluorescence mode achieves a detection limit (LOD) of 50 nM, while the electrochemical detection mode (using a carbon fiber microelectrode modified with carbon nanotubes (CFME/CNT)) has a detection range of 1.0-50 μM. Both modes exhibit excellent selectivity against other ROS and biomolecules. In vivo microdialysis analysis reveals significantly elevated H<sub>2</sub>O<sub>2</sub> levels in the brains of AD mice (28.6 ± 3.2 μM) compared with wild-type mice (10.3 ± 1.8 μM). This dual-mode strategy enables cross-validation, providing a reliable tool for monitoring oxidative stress in neurodegenerative diseases.

Analytical ChemistryVol. 97(49)
Zhengzhou University (CN), Ministry of Education (ME), Division of Materials Science and Engineering (AU), Xinxiang University (CN), Shangqiu Normal University (CN)
Openalex Percentile: Top 11%
Electrochemical sensors and biosensors
2.19
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.