A Fluid–Structure Interaction Computational Study of Residual Aortic Dissection to Investigate the Influence of Mechanical Behaviour of Wall and Flap on Flows

Residual thoracic aortic dissection (RTAD) is a pathology whose patient-dependent evolution is an important clinical issue, and for which numerical fluid-structure interaction (FSI) models can be helpful. However, the proposal of an ad hoc mechanical wall and flap model remains a challenge. To make progress on this issue, we seek to understand the respective influence of the flap and the wall in interaction with the flow in RTAD. Based on a patient's RTAD geometry, we established different FSI models to simulate the mechanical behaviour of the wall and flap. We varied the Young's modulus of the wall between 1.2 MPa (W12) and 2.7 MPa (W27) and the Young's modulus of the flap between 0.6 MPa (F06) and 1.2 MPa (F12), resulting in 3 different cases to study (F06W12, F12W12 and F06W27) and allowing a relative comparison. Structural displacements and stresses are equivalent in F06W12 and F12W12, resulting in equivalent flow characteristics. When comparing F06W12 with F06W27, we show that a stiffer wall reduces flap motion by 49.8%, 51% and 52% respectively, around the first entry tear, second and third one respectively. The difference in flow pressure between channels, which reflects the resistance to flow, is very small (about 1-2 mmHg) and similar for all 3 cases. This result seems to be highly related to the current geometry with one entry and two re-entry tears. Our results show that the wall is the main driver of the overall mechanical behaviour of the RTAD. We demonstrated that a stiffer pathological wall leads to smaller flap displacements, which is consistent with clinical observations in the chronic phase.

Authors

Institutions

Publication Details

Journal
International Journal for Numerical Methods in Biomedical Engineering
Published
2025-12-01
DOI
https://doi.org/10.1002/cnm.70120
Citations
1
Primary Topic
Aortic Disease and Treatment Approaches
Type
article
Field-Weighted Citation Impact
1.52
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

A Fluid–Structure Interaction Computational Study of Residual Aortic Dissection to Investigate the Influence of Mechanical Behaviour of Wall and Flap on Flows

Carine Guivier‐Curien, Valérie Deplano
1 citations
International Journal for Numerical Methods in Biomedical Engineering
Aortic Disease and Treatment Approaches
1.52
article

A Fluid–Structure Interaction Computational Study of Residual Aortic Dissection to Investigate the Influence of Mechanical Behaviour of Wall and Flap on Flows

Carine Guivier‐Curien, Valérie Deplano
article en
1 citations

Abstract

Residual thoracic aortic dissection (RTAD) is a pathology whose patient-dependent evolution is an important clinical issue, and for which numerical fluid-structure interaction (FSI) models can be helpful. However, the proposal of an ad hoc mechanical wall and flap model remains a challenge. To make progress on this issue, we seek to understand the respective influence of the flap and the wall in interaction with the flow in RTAD. Based on a patient's RTAD geometry, we established different FSI models to simulate the mechanical behaviour of the wall and flap. We varied the Young's modulus of the wall between 1.2 MPa (W12) and 2.7 MPa (W27) and the Young's modulus of the flap between 0.6 MPa (F06) and 1.2 MPa (F12), resulting in 3 different cases to study (F06W12, F12W12 and F06W27) and allowing a relative comparison. Structural displacements and stresses are equivalent in F06W12 and F12W12, resulting in equivalent flow characteristics. When comparing F06W12 with F06W27, we show that a stiffer wall reduces flap motion by 49.8%, 51% and 52% respectively, around the first entry tear, second and third one respectively. The difference in flow pressure between channels, which reflects the resistance to flow, is very small (about 1-2 mmHg) and similar for all 3 cases. This result seems to be highly related to the current geometry with one entry and two re-entry tears. Our results show that the wall is the main driver of the overall mechanical behaviour of the RTAD. We demonstrated that a stiffer pathological wall leads to smaller flap displacements, which is consistent with clinical observations in the chronic phase.

International Journal for Numerical Methods in Biomedical EngineeringVol. 41(12)
Centre National de la Recherche Scientifique (FR), Centrale Méditerranée (FR)
Openalex Percentile: Top 12%
Aortic Disease and Treatment Approaches
1.52
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

A Fluid–Structure Interaction Computational Study of Residual Aortic Dissection to Investigate the Influence of Mechanical Behaviour of Wall and Flap on Flows — Carine Guivier‐Curien, Valérie Deplano · International Journal for Numerical Methods in Biomedical Engineering (2025) | TGRS Research Map | TGRS