Investigation of indoor air quality at the underground shooting range for the training of police officers in Korea

Police officers in Korea undergo regular indoor firearms training, yet exposure to hazardous substances and ventilation effectiveness remain unassessed. This study evaluated air quality and metal concentrations in an underground indoor shooting range equipped with a mechanical ventilation system. Amongst 21 measured elements, lead (Pb) concentrations were from 218.1 to 983.5 µg/m 3 , with all samples exceeding the occupational exposure limit of 50 µg/m 3 . The 8-h time-weighted average for Pb exposure, based on a 20-min training session, was 59.3 µg/m 3 . Real-time measurements confirmed increases in fine particulate matter and carbon monoxide during shooting. Despite adequate ventilation rates, high Pb levels were attributed to ineffective airflow caused by the misplacement of supply and exhaust vents, both located behind the shooters. These findings highlight the urgent need for ventilation system redesign and exposure control in shooting ranges.

Authors

Institutions

Publication Details

Journal
Indoor and Built Environment
Published
2025-12-04
DOI
https://doi.org/10.1177/1420326x251391408
Primary Topic
Occupational Health and Performance
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Investigation of indoor air quality at the underground shooting range for the training of police officers in Korea

Jungwon Jang, Ju‐Hyun Park, Sangjun Choi, Yeji Sung et al.
Indoor and Built Environment
Occupational Health and Performance
article

Investigation of indoor air quality at the underground shooting range for the training of police officers in Korea

Jungwon Jang, Ju‐Hyun Park, Sangjun Choi, Yeji Sung, Inah Kim
article en

Abstract

Police officers in Korea undergo regular indoor firearms training, yet exposure to hazardous substances and ventilation effectiveness remain unassessed. This study evaluated air quality and metal concentrations in an underground indoor shooting range equipped with a mechanical ventilation system. Amongst 21 measured elements, lead (Pb) concentrations were from 218.1 to 983.5 µg/m 3 , with all samples exceeding the occupational exposure limit of 50 µg/m 3 . The 8-h time-weighted average for Pb exposure, based on a 20-min training session, was 59.3 µg/m 3 . Real-time measurements confirmed increases in fine particulate matter and carbon monoxide during shooting. Despite adequate ventilation rates, high Pb levels were attributed to ineffective airflow caused by the misplacement of supply and exhaust vents, both located behind the shooters. These findings highlight the urgent need for ventilation system redesign and exposure control in shooting ranges.

Indoor and Built EnvironmentVol. 35(2)
Dongguk University (KR), Hanyang University (KR), Catholic University of Korea (KR)
Openalex Percentile: Top 46%
Occupational Health and Performance
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Investigation of indoor air quality at the underground shooting range for the training of police officers in Korea — Jungwon Jang, Ju‐Hyun Park, et al. · Indoor and Built Environment (2025) | TGRS Research Map | TGRS