Effect of Print Orientation and Post-Curing Duration on the Flexural Strength, Flexural Modulus and Vickers Microhardness of a 3D-Printed Occlusal Splint Resin

Additive manufacturing (AM) offers precision and efficiency in occlusal splint fabrication; however, the combined influence of build orientation and post-curing duration on the mechanical performance of splint resins remains insufficiently explored. This in vitro experimental study evaluated the effects of three build orientations (0°, 45°, and 90°) and three post-curing protocols (uncured, standard, and extended) on the flexural strength (FS), flexural modulus (FM) and Vickers hardness number (VHN) of a Class IIa biocompatible occlusal splint resin (NextDent Ortho Rigid). A total of 180 specimens were fabricated using a vat polymerization-type 3D printing system. Statistical analyses were conducted using one-way analyses of variance and Tukey's tests at a significance level of α = 0.05. Both build orientation and post-curing duration significantly affected FS and VHN (<i>p</i> < 0.001). The combination of 45° build orientations and extended post-curing produced the highest FS (169.76 MPa) and FM (7502.17 MPa), exceeding values typically reported for 3D-printed splints, while the 90° orientation with extended curing achieved the highest VHN (21.88). Hardness gains, however, plateaued beyond standard curing, indicating a trade-off between strength and surface hardness. These results demonstrate that print orientation and post-curing time are decisive parameters in optimizing the mechanical performance of 3D-printed occlusal splints. For high-load clinical applications such as bruxism, prioritizing flexural strength over surface hardness may improve appliance longevity, supporting 45° orientation with extended curing as an evidence-based manufacturing approach.

Authors

Institutions

Publication Details

Journal
Bioengineering
Published
2025-12-04
DOI
https://doi.org/10.3390/bioengineering12121322
Citations
1
Primary Topic
Dental materials and restorations
Type
article
Field-Weighted Citation Impact
1.68
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Effect of Print Orientation and Post-Curing Duration on the Flexural Strength, Flexural Modulus and Vickers Microhardness of a 3D-Printed Occlusal Splint Resin

Süleyman Kutalmış Büyük, Hüseyin Şimşek, Mustafa Sahin, M. Serdar Toroğlu et al.
1 citations
Bioengineering
Dental materials and restorations
1.68
article

Effect of Print Orientation and Post-Curing Duration on the Flexural Strength, Flexural Modulus and Vickers Microhardness of a 3D-Printed Occlusal Splint Resin

Süleyman Kutalmış Büyük, Hüseyin Şimşek, Mustafa Sahin, M. Serdar Toroğlu, Tuncer Akdoğan, Safiyenur Bircan
article en
1 citations

Abstract

Additive manufacturing (AM) offers precision and efficiency in occlusal splint fabrication; however, the combined influence of build orientation and post-curing duration on the mechanical performance of splint resins remains insufficiently explored. This in vitro experimental study evaluated the effects of three build orientations (0°, 45°, and 90°) and three post-curing protocols (uncured, standard, and extended) on the flexural strength (FS), flexural modulus (FM) and Vickers hardness number (VHN) of a Class IIa biocompatible occlusal splint resin (NextDent Ortho Rigid). A total of 180 specimens were fabricated using a vat polymerization-type 3D printing system. Statistical analyses were conducted using one-way analyses of variance and Tukey's tests at a significance level of α = 0.05. Both build orientation and post-curing duration significantly affected FS and VHN (<i>p</i> < 0.001). The combination of 45° build orientations and extended post-curing produced the highest FS (169.76 MPa) and FM (7502.17 MPa), exceeding values typically reported for 3D-printed splints, while the 90° orientation with extended curing achieved the highest VHN (21.88). Hardness gains, however, plateaued beyond standard curing, indicating a trade-off between strength and surface hardness. These results demonstrate that print orientation and post-curing time are decisive parameters in optimizing the mechanical performance of 3D-printed occlusal splints. For high-load clinical applications such as bruxism, prioritizing flexural strength over surface hardness may improve appliance longevity, supporting 45° orientation with extended curing as an evidence-based manufacturing approach.

BioengineeringVol. 12(12)
Cukurova University (TR), Ordu University (TR)
Openalex Percentile: Top 13%
Dental materials and restorations
1.68
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.