Safety classification of line lasers as extended source

Line lasers are good examples to discuss the safety classification of a laser product as extended source according to IEC 60825-1. It is necessary to consider different accommodations of the eye, from accommodation to the beam waist in the diverging axis (the vertex of the line) to accommodation to infinity, which results in a retinal line image. Measurements and the classification analyses were performed for a common line laser. It was found that accommodation to the beam waist in the diverging axis produces the most critical retinal image and can be considered as “the apparent source.” Compared to the classification as a small source, classification as an extended source permits a factor of 5.8 higher power output. We argue that performing direct retinal image measurements with a CCD camera is more accurate and requires less effort than measuring beam parameters in the two axes and calculating the relevant parameters.

Authors

Institutions

Publication Details

Journal
Journal of Laser Applications
Published
2025-12-04
DOI
https://doi.org/10.2351/7.0001810
Primary Topic
Ocular and Laser Science Research
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Safety classification of line lasers as extended source

Sarah Nagl, Karl Schulmeister, Reinhard Gilber
Journal of Laser Applications
Ocular and Laser Science Research
article

Safety classification of line lasers as extended source

Sarah Nagl, Karl Schulmeister, Reinhard Gilber
article en

Abstract

Line lasers are good examples to discuss the safety classification of a laser product as extended source according to IEC 60825-1. It is necessary to consider different accommodations of the eye, from accommodation to the beam waist in the diverging axis (the vertex of the line) to accommodation to infinity, which results in a retinal line image. Measurements and the classification analyses were performed for a common line laser. It was found that accommodation to the beam waist in the diverging axis produces the most critical retinal image and can be considered as “the apparent source.” Compared to the classification as a small source, classification as an extended source permits a factor of 5.8 higher power output. We argue that performing direct retinal image measurements with a CCD camera is more accurate and requires less effort than measuring beam parameters in the two axes and calculating the relevant parameters.

Journal of Laser ApplicationsVol. 38(1)
Seibersdorf Laboratories (Austria) (AT)
Openalex Percentile: Top 47%
Ocular and Laser Science Research
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.