Comparison of MRI-, CT- and PET-based anatomical standardization for Centiloid scale calculation in [18F]florbetapir positron emission tomography

The Centiloid (CL) method is a standardized quantitative approach for amyloid positron emission tomography (PET) that involves the anatomical standardization of PET images. The Global Alzheimer’s Association Interactive Network recommends performing this anatomical standardization using contemporaneously acquired three-dimensional (3D) T1-weighted magnetic resonance imaging (MRI). However, in clinical practice, contemporaneous 3D T1WI is not always available due to outdated imaging or missing sequences. Recently, alternative methods utilizing low-dose computed tomography (CT) scan images from PET/CT scan or PET images themselves for anatomical standardization have been proposed and implemented in commercially available software. This study aimed to compare the CL obtained via MRI-based standardization with CT scan-based and PET-only standardizations. Further, the clinical applicability of these alternative methods was assessed. We retrospectively analyzed 68 patients who underwent [18 F]florbetapir PET/CT scan imaging. The CL were calculated using two commercially available software programs—AMYclz® Neuro (PDR Pharma, Tokyo) and BRAINEER® Model A (Splink, Tokyo)—under three conditions: anatomical standardization with MRI, CT scan, and a PET-derived template. The correlations and differences among these methods were evaluated. 68 patients (age: 70.8 ± 11.2) were included in the analysis. The median CL was 33.87 (3.53–76.57). CT scan-based standardization had lower CL than MRI-based standardization (mean difference: −5.9 ± 4.8). Meanwhile, PET-only standardization had slightly lower CL than MRI-based standardization (-2.1 ± 11.0). The differences in the CL were generally within ± 15. In cases with evidently positive (CL ≥ 50) or clearly negative (CL ≤ 5) findings, the omission of MRI did not affect exceeding the threshold. When contemporaneous 3D T1WI is not available, CT scan-based or PET-only anatomical standardization can be a practical alternative for the qualitative assessment of amyloid PET. However, users should recognize that CT scan-based methods have a systematic tendency to underestimate CL values compared with MRI-based methods. Meanwhile, PET-only methods have a tendency to slightly underestimate CL values. The omission of MRI may be acceptable for clear positive or negative cases. However, caution is required for borderline cases, particularly in situations requiring precise quantification such as treatment monitoring.

Authors

Institutions

Publication Details

Journal
Annals of Nuclear Medicine
Published
2025-12-04
DOI
https://doi.org/10.1007/s12149-025-02134-4
Primary Topic
Dementia and Cognitive Impairment Research
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Comparison of MRI-, CT- and PET-based anatomical standardization for Centiloid scale calculation in [18F]florbetapir positron emission tomography

Takanori Yokota, Ukihide Tateishi, Yoichiro Nishida, Kota Yokoyama et al.
Annals of Nuclear Medicine
Dementia and Cognitive Impairment Research
article

Comparison of MRI-, CT- and PET-based anatomical standardization for Centiloid scale calculation in [18F]florbetapir positron emission tomography

Takanori Yokota, Ukihide Tateishi, Yoichiro Nishida, Kota Yokoyama, Jun Oyama, Junichi Tsuchiya, Masahito Yamada, Hirofumi Yamada, Nobuo Sanjyo
article en

Abstract

The Centiloid (CL) method is a standardized quantitative approach for amyloid positron emission tomography (PET) that involves the anatomical standardization of PET images. The Global Alzheimer’s Association Interactive Network recommends performing this anatomical standardization using contemporaneously acquired three-dimensional (3D) T1-weighted magnetic resonance imaging (MRI). However, in clinical practice, contemporaneous 3D T1WI is not always available due to outdated imaging or missing sequences. Recently, alternative methods utilizing low-dose computed tomography (CT) scan images from PET/CT scan or PET images themselves for anatomical standardization have been proposed and implemented in commercially available software. This study aimed to compare the CL obtained via MRI-based standardization with CT scan-based and PET-only standardizations. Further, the clinical applicability of these alternative methods was assessed. We retrospectively analyzed 68 patients who underwent [18 F]florbetapir PET/CT scan imaging. The CL were calculated using two commercially available software programs—AMYclz® Neuro (PDR Pharma, Tokyo) and BRAINEER® Model A (Splink, Tokyo)—under three conditions: anatomical standardization with MRI, CT scan, and a PET-derived template. The correlations and differences among these methods were evaluated. 68 patients (age: 70.8 ± 11.2) were included in the analysis. The median CL was 33.87 (3.53–76.57). CT scan-based standardization had lower CL than MRI-based standardization (mean difference: −5.9 ± 4.8). Meanwhile, PET-only standardization had slightly lower CL than MRI-based standardization (-2.1 ± 11.0). The differences in the CL were generally within ± 15. In cases with evidently positive (CL ≥ 50) or clearly negative (CL ≤ 5) findings, the omission of MRI did not affect exceeding the threshold. When contemporaneous 3D T1WI is not available, CT scan-based or PET-only anatomical standardization can be a practical alternative for the qualitative assessment of amyloid PET. However, users should recognize that CT scan-based methods have a systematic tendency to underestimate CL values compared with MRI-based methods. Meanwhile, PET-only methods have a tendency to slightly underestimate CL values. The omission of MRI may be acceptable for clear positive or negative cases. However, caution is required for borderline cases, particularly in situations requiring precise quantification such as treatment monitoring.

Annals of Nuclear MedicineVol. 40(3)
Bunkyo University (JP), Tokyo Metropolitan Institute of Medical Science (JP), Kudanzaka Hospital (JP)
Openalex Percentile: Top 55%
Dementia and Cognitive Impairment Research
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.