Investigation of ultrasound plane-wave imaging for optimal synthetic focusing

Plane-wave imaging for ultrafast ultrasound, revolutionized by substantially enhancing frame rates, has paved the way for numerous applications in medical ultrasound. To improve spatial resolution and contrast, plane-wave compounding is typically utilized. Plane-wave compounding, referred to as plane-wave synthetic focusing (PW-SF) in this study, coherently sums the echoes from plane waves steered at multiple angles. To further improve the image quality and reduce the computational complexity for PW-SF, this study investigates the impact of plane-wave angle distributions and beamforming grids. Plane-wave angles with evenly selected in the radian space and in the sine of radian space, referred to as $$\theta$$-even and $$\alpha$$-even angles, respectively, are analytically derived. For the beamforming grids, we apply a plane-wave pixel-based synthetic focusing (PW-PBSF) approach, directly focusing echoes on display pixels, to achieve the optimal image quality in terms of resolution and computational complexity. From the simulation and phantom experiment, the largest improvement in lateral resolution was observed with PW-PBSF [0.16 mm], which produced 0.29 mm compared with 0.35 mm for PW-SF-256, corresponding to approximately a 17% enhancement. The $$\alpha$$-even angle discretization approach also provided higher contrast, contrast-to-noise ratio (CNR), and generalized contrast-to-noise ratio (gCNR) values, measured as 5.72 dB, 1.54, and 0.841 dB, respectively whereas $$\theta$$-even yielded 5.58 dB, 1.51, and 0.814. Consistent with the phantom findings, In vivo imaging of carotid artery also demonstrated that the PW-PBSF can provide improved resolution of plane-wave images without incurring redundant computational costs.

Authors

Institutions

Publication Details

Journal
Scientific Reports
Published
2025-12-04
DOI
https://doi.org/10.1038/s41598-025-30595-0
Primary Topic
Ultrasound Imaging and Elastography
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Investigation of ultrasound plane-wave imaging for optimal synthetic focusing

Heechul Yoon, Tai‐Kyong Song, Jae Hee Song, Jaebum Park et al.
Scientific Reports
Ultrasound Imaging and Elastography
article

Investigation of ultrasound plane-wave imaging for optimal synthetic focusing

Heechul Yoon, Tai‐Kyong Song, Jae Hee Song, Jaebum Park, Doyoung Jang
article en

Abstract

Plane-wave imaging for ultrafast ultrasound, revolutionized by substantially enhancing frame rates, has paved the way for numerous applications in medical ultrasound. To improve spatial resolution and contrast, plane-wave compounding is typically utilized. Plane-wave compounding, referred to as plane-wave synthetic focusing (PW-SF) in this study, coherently sums the echoes from plane waves steered at multiple angles. To further improve the image quality and reduce the computational complexity for PW-SF, this study investigates the impact of plane-wave angle distributions and beamforming grids. Plane-wave angles with evenly selected in the radian space and in the sine of radian space, referred to as $$\theta$$-even and $$\alpha$$-even angles, respectively, are analytically derived. For the beamforming grids, we apply a plane-wave pixel-based synthetic focusing (PW-PBSF) approach, directly focusing echoes on display pixels, to achieve the optimal image quality in terms of resolution and computational complexity. From the simulation and phantom experiment, the largest improvement in lateral resolution was observed with PW-PBSF [0.16 mm], which produced 0.29 mm compared with 0.35 mm for PW-SF-256, corresponding to approximately a 17% enhancement. The $$\alpha$$-even angle discretization approach also provided higher contrast, contrast-to-noise ratio (CNR), and generalized contrast-to-noise ratio (gCNR) values, measured as 5.72 dB, 1.54, and 0.841 dB, respectively whereas $$\theta$$-even yielded 5.58 dB, 1.51, and 0.814. Consistent with the phantom findings, In vivo imaging of carotid artery also demonstrated that the PW-PBSF can provide improved resolution of plane-wave images without incurring redundant computational costs.

Scientific ReportsVol. 16(1)
Sogang University (KR), The University of Queensland (AU), Dankook University (KR)
Korea Medical Device Development Fund, National Research Foundation, Ministry of Trade, Industry and Energy, Ministry of Food and Drug Safety, National Research Foundation of Korea, Ministry of Science and ICT, South Korea, Institute for Information and Communications Technology Promotion
Openalex Percentile: Top 47%
Ultrasound Imaging and Elastography
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.