Time-Scale-Resolved Capacitance and Relaxation-Time Analysis of Glucose Electrooxidation on NiO Electrodes

Electrochemical impedance spectroscopy (EIS) is one of the essential tools for probing interfacial charge transfer in electrochemical systems. Transforming impedance data into alternative domains can reveal hidden processes that are masked in the frequency domain. In the present study, we investigate glucose oxidation on NiO by combining electrochemical capacitance spectroscopy (ECS) and the distribution of relaxation times (DRT). NiO was prepared via thermal decomposition and characterized structurally. Then, we show how capacitance analysis separates double layer and pseudocapacitive contributions, while DRT provides time-resolved insights into the individual electrochemical steps. Using ECS, we observe that increasing glucose concentration (0 to 5 mM) enhances pseudocapacitance and reduces charge transfer resistance. ECS also reveals that the low frequency capacitance increases linearly with glucose concentration, whereas the double layer capacitance remains constant. On the other hand, DRT spectra exhibit two peaks, which we attribute to two processes: a fast process associated with OH<sup>-</sup> adsorption and a slower process attributed to direct glucose oxidation. The dominant peak shifts to shorter relaxation times and decreases in amplitude with increasing glucose, consistent with accelerated kinetics and lower resistance. DRT signatures of ascorbic acid, dopamine and uric acid differ from that of glucose, demonstrating selectivity. These findings establish, for the first time, the DRT as a powerful time scale domain transduction method that critically complements ECS, and offers mechanistic insights for the advanced design of non-enzymatic glucose sensors for diabetes monitoring.

Authors

Institutions

Publication Details

Journal
The Journal of Physical Chemistry Letters
Published
2025-12-04
DOI
https://doi.org/10.1021/acs.jpclett.5c03318
Primary Topic
Electrochemical sensors and biosensors
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Time-Scale-Resolved Capacitance and Relaxation-Time Analysis of Glucose Electrooxidation on NiO Electrodes

Francesco Ciucci, Baptiste Py, Kavita Pandey, Arya Kannathvalappil
The Journal of Physical Chemistry Letters
Electrochemical sensors and biosensors
article

Time-Scale-Resolved Capacitance and Relaxation-Time Analysis of Glucose Electrooxidation on NiO Electrodes

Francesco Ciucci, Baptiste Py, Kavita Pandey, Arya Kannathvalappil
article en

Abstract

Electrochemical impedance spectroscopy (EIS) is one of the essential tools for probing interfacial charge transfer in electrochemical systems. Transforming impedance data into alternative domains can reveal hidden processes that are masked in the frequency domain. In the present study, we investigate glucose oxidation on NiO by combining electrochemical capacitance spectroscopy (ECS) and the distribution of relaxation times (DRT). NiO was prepared via thermal decomposition and characterized structurally. Then, we show how capacitance analysis separates double layer and pseudocapacitive contributions, while DRT provides time-resolved insights into the individual electrochemical steps. Using ECS, we observe that increasing glucose concentration (0 to 5 mM) enhances pseudocapacitance and reduces charge transfer resistance. ECS also reveals that the low frequency capacitance increases linearly with glucose concentration, whereas the double layer capacitance remains constant. On the other hand, DRT spectra exhibit two peaks, which we attribute to two processes: a fast process associated with OH<sup>-</sup> adsorption and a slower process attributed to direct glucose oxidation. The dominant peak shifts to shorter relaxation times and decreases in amplitude with increasing glucose, consistent with accelerated kinetics and lower resistance. DRT signatures of ascorbic acid, dopamine and uric acid differ from that of glucose, demonstrating selectivity. These findings establish, for the first time, the DRT as a powerful time scale domain transduction method that critically complements ECS, and offers mechanistic insights for the advanced design of non-enzymatic glucose sensors for diabetes monitoring.

The Journal of Physical Chemistry LettersVol. 16(49)
Hong Kong University of Science and Technology (HK), Centre for Nano and Soft Matter Sciences (IN), University of Bayreuth (DE), Academy of Scientific and Innovative Research (IN)
Openalex Percentile: Top 61%
Electrochemical sensors and biosensors
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.