A Smart Dual-Amplification Electrochemical Analyzer: Product-Activated Tripedal DNA Walker for Glioma Grading

Accurate quantification of low-concentration tumor-derived miRNAs in complex biological samples is critical for cancer clinical diagnosis yet remains challenging due to the lack of convenient and sensitive detection methods. Herein, we report a smart dual-amplification electrochemical analyzer (SDEA) for glioma grading based on product-activated tripedal DNA walker. Target miRNA initiates strand displacement amplification to generate abundant specific DNA strands that release walker strands. The SDEA strategy circumvents nonspecific binding between the potential interferent and the DNA walker. In addition, two-round amplification is involved, including strand displacement amplification and tripedal DNA walking, promising high sensitivity for target miRNA detection. The proposed SDEA allows staging analysis of gliomas in clinical cohorts and highlights the great potential of DNA nanotechnology in disease diagnostics.

Authors

Institutions

Publication Details

Journal
Analytical Chemistry
Published
2025-12-04
DOI
https://doi.org/10.1021/acs.analchem.5c07010
Primary Topic
Advanced biosensing and bioanalysis techniques
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

A Smart Dual-Amplification Electrochemical Analyzer: Product-Activated Tripedal DNA Walker for Glioma Grading

Peng Miao, Tao Cheng, Zhenghe Xu, Jian Sun et al.
Analytical Chemistry
Advanced biosensing and bioanalysis techniques
article

A Smart Dual-Amplification Electrochemical Analyzer: Product-Activated Tripedal DNA Walker for Glioma Grading

Peng Miao, Tao Cheng, Zhenghe Xu, Jian Sun, Jin Jiao, Jiabao Yu
article en

Abstract

Accurate quantification of low-concentration tumor-derived miRNAs in complex biological samples is critical for cancer clinical diagnosis yet remains challenging due to the lack of convenient and sensitive detection methods. Herein, we report a smart dual-amplification electrochemical analyzer (SDEA) for glioma grading based on product-activated tripedal DNA walker. Target miRNA initiates strand displacement amplification to generate abundant specific DNA strands that release walker strands. The SDEA strategy circumvents nonspecific binding between the potential interferent and the DNA walker. In addition, two-round amplification is involved, including strand displacement amplification and tripedal DNA walking, promising high sensitivity for target miRNA detection. The proposed SDEA allows staging analysis of gliomas in clinical cohorts and highlights the great potential of DNA nanotechnology in disease diagnostics.

Analytical ChemistryVol. 97(49)
University of Science and Technology of China (CN), Academy of Medical Sciences (GB), Chinese Academy of Sciences (CN), Suzhou Institute of Biomedical Engineering and Technology (CN), Shandong Tumor Hospital (CN), Shandong First Medical University (CN)
Openalex Percentile: Top 65%
Advanced biosensing and bioanalysis techniques
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

A Smart Dual-Amplification Electrochemical Analyzer: Product-Activated Tripedal DNA Walker for Glioma Grading — Peng Miao, Tao Cheng, et al. · Analytical Chemistry (2025) | TGRS Research Map | TGRS