Verification testing in a multi‐laboratory system using <scp>ANSI</scp> / <scp>ASB</scp> Standard 020

Protocol verification is a fit-for-purpose test of laboratory procedures. We present here verification testing of a DNA mixture interpretation protocol, following ANSI/ASB Standard 020, Standard for Validation Studies of DNA Mixtures, and Development and Verification of a Laboratory's Mixture Interpretation Protocol. The blind testing called for in the standard was performed on a set of nine DNA mixtures created with contributors unique to the verification, using a range of donor ratios (distinguishable and indistinguishable), DNA inputs (0.25-3.6 ng), and numbers of contributors (2-4). The testers ("verifiers") were given .hid files, along with limited contextual information that simulated the state of caseworker knowledge prior to PCR amplification, and they were tasked with determining contributor number and suitability for interpretation, analyzing each interpretable mixture, and generating simple likelihood ratios (LRs) and corresponding verbal predicate assignments. Although the differences observed across verifiers were within the scope of the draft mixture interpretation procedure and resulted in non-consequential differences among the calculated LRs, we found that the process led to significant improvements in training efficiency and pre-release protocol refinement. We also found that DNA mixture selection, verifier training prior to verification testing, and assessment criteria development must all be considered carefully to make the process as effective as possible, particularly in a multi-laboratory system. The planning and results summarized in this paper can serve as a template to other forensic DNA laboratories seeking to incorporate the recommendations of ANSI/ASB Standard 020 into their quality assurance systems.

Authors

Institutions

Publication Details

Journal
Journal of Forensic Sciences
Published
2025-12-03
DOI
https://doi.org/10.1111/1556-4029.70236
Primary Topic
Forensic and Genetic Research
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Verification testing in a multi‐laboratory system using ANSI / ASB Standard 020

Daniela Cuenca, Jeanette M. Wallin, Kyle Duke, Steven Myers
Journal of Forensic Sciences
Forensic and Genetic Research
article

Verification testing in a multi‐laboratory system using ANSI / ASB Standard 020

Daniela Cuenca, Jeanette M. Wallin, Kyle Duke, Steven Myers
article en

Abstract

Protocol verification is a fit-for-purpose test of laboratory procedures. We present here verification testing of a DNA mixture interpretation protocol, following ANSI/ASB Standard 020, Standard for Validation Studies of DNA Mixtures, and Development and Verification of a Laboratory's Mixture Interpretation Protocol. The blind testing called for in the standard was performed on a set of nine DNA mixtures created with contributors unique to the verification, using a range of donor ratios (distinguishable and indistinguishable), DNA inputs (0.25-3.6 ng), and numbers of contributors (2-4). The testers ("verifiers") were given .hid files, along with limited contextual information that simulated the state of caseworker knowledge prior to PCR amplification, and they were tasked with determining contributor number and suitability for interpretation, analyzing each interpretable mixture, and generating simple likelihood ratios (LRs) and corresponding verbal predicate assignments. Although the differences observed across verifiers were within the scope of the draft mixture interpretation procedure and resulted in non-consequential differences among the calculated LRs, we found that the process led to significant improvements in training efficiency and pre-release protocol refinement. We also found that DNA mixture selection, verifier training prior to verification testing, and assessment criteria development must all be considered carefully to make the process as effective as possible, particularly in a multi-laboratory system. The planning and results summarized in this paper can serve as a template to other forensic DNA laboratories seeking to incorporate the recommendations of ANSI/ASB Standard 020 into their quality assurance systems.

Journal of Forensic SciencesVol. 71(2)
United States Department of Justice (US)
Openalex Percentile: Top 60%
Forensic and Genetic Research
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Verification testing in a multi‐laboratory system using <scp>ANSI</scp> / <scp>ASB</scp> Standard 020 — Daniela Cuenca, Jeanette M. Wallin, et al. · Journal of Forensic Sciences (2025) | TGRS Research Map | TGRS