Design and Development of Pulsatile Cardiovascular Flow Simulator and Comparative Assessment of Flow through Stenosed Blood Vessel

The design, development, and validation of a physiological pulsatile cardiovascular flow simulator to analyse the hemodynamic behaviour in stenosed blood vessels is studied. The simulator consists of an innovative arrangement of peristaltic pumps to reproduce realistic arterial pulse waveforms, incorporating the higher harmonic components of physiological flow. Experimental investigations were performed using a laser Doppler velocimetry (LDV) system to evaluate the axial velocity, the wall shear stress (WSS), the turbulence intensity, and related flow parameters in vessels with varying stenosis severities (12.5, 25, and 50%). The observed results indicated that stenosis severity critically influences the flow structure, with higher blockages inducing significant velocity skewness, increased oscillatory WSS, and sustained post-stenotic disturbances. Flow reversal, vortex formation, and prolonged laminar recovery were observed downstream of severe stenoses. Comparative analyses with theoretical models validated the experimental accuracy, particularly in central and mid-radial zones. The study also introduced a method for determining the oscillatory shear index (OSI) and the relative residence time (RRT), identifying regions susceptible to atherogenesis. The simulator provides a reliable platform for replicating in vivo-like flow patterns in vitro, providing the valuable insights into the disease progression mechanisms and enabling future development of diagnostic and interventional strategies in cardiovascular medicine.

Authors

Institutions

Publication Details

Journal
Fluid Dynamics
Published
2025-12-01
DOI
https://doi.org/10.1134/s0015462825602037
Primary Topic
Coronary Interventions and Diagnostics
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Design and Development of Pulsatile Cardiovascular Flow Simulator and Comparative Assessment of Flow through Stenosed Blood Vessel

Kedar Deshmukh, Himadri Chattopadhyay, Arindam Bit, Ali Cemal Beni̇m et al.
Fluid Dynamics
Coronary Interventions and Diagnostics
article

Design and Development of Pulsatile Cardiovascular Flow Simulator and Comparative Assessment of Flow through Stenosed Blood Vessel

Kedar Deshmukh, Himadri Chattopadhyay, Arindam Bit, Ali Cemal Beni̇m, Rinku Mukherjee
article en

Abstract

The design, development, and validation of a physiological pulsatile cardiovascular flow simulator to analyse the hemodynamic behaviour in stenosed blood vessels is studied. The simulator consists of an innovative arrangement of peristaltic pumps to reproduce realistic arterial pulse waveforms, incorporating the higher harmonic components of physiological flow. Experimental investigations were performed using a laser Doppler velocimetry (LDV) system to evaluate the axial velocity, the wall shear stress (WSS), the turbulence intensity, and related flow parameters in vessels with varying stenosis severities (12.5, 25, and 50%). The observed results indicated that stenosis severity critically influences the flow structure, with higher blockages inducing significant velocity skewness, increased oscillatory WSS, and sustained post-stenotic disturbances. Flow reversal, vortex formation, and prolonged laminar recovery were observed downstream of severe stenoses. Comparative analyses with theoretical models validated the experimental accuracy, particularly in central and mid-radial zones. The study also introduced a method for determining the oscillatory shear index (OSI) and the relative residence time (RRT), identifying regions susceptible to atherogenesis. The simulator provides a reliable platform for replicating in vivo-like flow patterns in vitro, providing the valuable insights into the disease progression mechanisms and enabling future development of diagnostic and interventional strategies in cardiovascular medicine.

Fluid DynamicsVol. 60(6)
Jadavpur University (IN), Bursa Technical University (TR), Kazan Federal University (RU), Indian Institute of Technology Gandhinagar (IN), National Institute of Technology Raipur (IN), Mody University of Science and Technology (IN), Hochschule Düsseldorf University of Applied Sciences (DE)
Openalex Percentile: Top 42%
Coronary Interventions and Diagnostics
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.