The diagnostic performance of ss-EPI-DWI, rs-EPI-DWI (RESOLVE) and TGSE-BLADE-DWI in a model of retinal ischemia: a comparative phantom study

This study systematically compared the performance of ss-EPI-DWI, rs-EPI-DWI (RESOLVE), and TGSE-BLADE-DWI for detecting small ischemic lesions (10 -2 mm) using a DWI phantom to gain insights for optimization of microstructural orbital MRI for retinal ischemia diagnosis. A DWI phantom simulating ischemic lesions embedded in healthy neuronal tissue was used to quantitatively and qualitatively assess the sequences at 3T. Signal-to-noise-ratio (SNR), contrast-to-noise-ratio (CNR), relative contrast (ReCon), geometric distortion rate (GDR) and apparent diffusion coefficient (ADC) accuracy were measured, with correlation analysis examining the effect of lesion size. Qualitative analysis was performed by two neuroradiologists evaluating the images in different criteria using a 5-point Likert scale. Among all sequences rs-EPI-DWI showed the most precise ADC (p < 0.001), highest CNR (p < 0.001) and relative contrast (p < 0.001) and non-inferiority to ss-EPI-DWI in SNR (p = 0.06). Both TGSE-BLADE-DWI and rs-EPI-DWI showed less GDR and susceptibility artifacts than ss-EPI-DWI qualitatively. All sequences depicted even the 2 mm lesion qualitatively; however, lesion size most strongly affected TGSE-BLADE-DWI quantitatively. Therefore, rs-EPI-DWI and TGSE-BLADE-DWI are promising alternatives to conventional ss-EPI-DWI for microstructural orbital MRI and may prove useful for clinical diagnosis of acute retinal ischemia due to high spatial resolution with reliable ADC acquisition, low geometric distortion and reduced susceptibility artifacts.

Authors

Institutions

Publication Details

Journal
Scientific Reports
Published
2025-12-03
DOI
https://doi.org/10.1038/s41598-025-30769-w
Primary Topic
Advanced Neuroimaging Techniques and Applications
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

The diagnostic performance of ss-EPI-DWI, rs-EPI-DWI (RESOLVE) and TGSE-BLADE-DWI in a model of retinal ischemia: a comparative phantom study

Eberhard Siebert, Michael Scheel, Sebastian Vellmer, Shakhnaz Guseynova et al.
Scientific Reports
Advanced Neuroimaging Techniques and Applications
article

The diagnostic performance of ss-EPI-DWI, rs-EPI-DWI (RESOLVE) and TGSE-BLADE-DWI in a model of retinal ischemia: a comparative phantom study

Eberhard Siebert, Michael Scheel, Sebastian Vellmer, Shakhnaz Guseynova, Alexander Schütze, Yannick Schröder
article en

Abstract

This study systematically compared the performance of ss-EPI-DWI, rs-EPI-DWI (RESOLVE), and TGSE-BLADE-DWI for detecting small ischemic lesions (10 -2 mm) using a DWI phantom to gain insights for optimization of microstructural orbital MRI for retinal ischemia diagnosis. A DWI phantom simulating ischemic lesions embedded in healthy neuronal tissue was used to quantitatively and qualitatively assess the sequences at 3T. Signal-to-noise-ratio (SNR), contrast-to-noise-ratio (CNR), relative contrast (ReCon), geometric distortion rate (GDR) and apparent diffusion coefficient (ADC) accuracy were measured, with correlation analysis examining the effect of lesion size. Qualitative analysis was performed by two neuroradiologists evaluating the images in different criteria using a 5-point Likert scale. Among all sequences rs-EPI-DWI showed the most precise ADC (p < 0.001), highest CNR (p < 0.001) and relative contrast (p < 0.001) and non-inferiority to ss-EPI-DWI in SNR (p = 0.06). Both TGSE-BLADE-DWI and rs-EPI-DWI showed less GDR and susceptibility artifacts than ss-EPI-DWI qualitatively. All sequences depicted even the 2 mm lesion qualitatively; however, lesion size most strongly affected TGSE-BLADE-DWI quantitatively. Therefore, rs-EPI-DWI and TGSE-BLADE-DWI are promising alternatives to conventional ss-EPI-DWI for microstructural orbital MRI and may prove useful for clinical diagnosis of acute retinal ischemia due to high spatial resolution with reliable ADC acquisition, low geometric distortion and reduced susceptibility artifacts.

Scientific ReportsVol. 15(1)
Charité - Universitätsmedizin Berlin (DE)
Openalex Percentile: Top 47%
Advanced Neuroimaging Techniques and Applications
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

The diagnostic performance of ss-EPI-DWI, rs-EPI-DWI (RESOLVE) and TGSE-BLADE-DWI in a model of retinal ischemia: a comparative phantom study — Eberhard Siebert, Michael Scheel, et al. · Scientific Reports (2025) | TGRS Research Map | TGRS