Positional Embedding Comparison for Improved 1-D Convolutional Transformer Hybrid Neural Network Fault Diagnosis on Power Converters

A comparative analysis on different positional encoders in a 1-D Convolution Transformer Hybrid Neural Network for Open Switch Fault Detection and Localization in a multilevel Cascaded H-Bridge (CHB) Converter is presented in this paper. Specifically, the performance efficacy evaluation of the sinusoidal, rotational and learnable positional encoders are compared, demonstrating their performance on multi-class classification models for open-circuit switch fault detection and localization. The models are applied for detecting the overall system health status, localizing faulty phase modules and single switch faults, respectively achieving accuracy values reaching 99% in each case of the three-level CHB converter. Additionally, Fourier positional encoder, T5 positional encoder and Relative positional encoder were considered in the seven-level CHB converter which in each cases the accuracy is above 95 %.

Authors

Institutions

Publication Details

Published
2025-10-19
DOI
https://doi.org/10.1109/ecce58356.2025.11260335
Primary Topic
Power Systems Fault Detection
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Positional Embedding Comparison for Improved 1-D Convolutional Transformer Hybrid Neural Network Fault Diagnosis on Power Converters

Giansalvo Cirrincione, Pericle Zanchetta, Maurizio Cirrincione, Giulia Tresca et al.
Power Systems Fault Detection
article

Positional Embedding Comparison for Improved 1-D Convolutional Transformer Hybrid Neural Network Fault Diagnosis on Power Converters

Giansalvo Cirrincione, Pericle Zanchetta, Maurizio Cirrincione, Giulia Tresca, Samuela Rokocakau, Farnoush Shamsazad
article en

Abstract

A comparative analysis on different positional encoders in a 1-D Convolution Transformer Hybrid Neural Network for Open Switch Fault Detection and Localization in a multilevel Cascaded H-Bridge (CHB) Converter is presented in this paper. Specifically, the performance efficacy evaluation of the sinusoidal, rotational and learnable positional encoders are compared, demonstrating their performance on multi-class classification models for open-circuit switch fault detection and localization. The models are applied for detecting the overall system health status, localizing faulty phase modules and single switch faults, respectively achieving accuracy values reaching 99% in each case of the three-level CHB converter. Additionally, Fourier positional encoder, T5 positional encoder and Relative positional encoder were considered in the seven-level CHB converter which in each cases the accuracy is above 95 %.

University of Pavia (IT), Charles Darwin University (AU), Université de Picardie Jules Verne (FR)
Openalex Percentile: Top 53%
Power Systems Fault Detection
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Positional Embedding Comparison for Improved 1-D Convolutional Transformer Hybrid Neural Network Fault Diagnosis on Power Converters — Giansalvo Cirrincione, Pericle Zanchetta, et al. · (2025) | TGRS Research Map | TGRS