Pulmonary embolism of subdermal contraceptive implant: lung-sparing precision removal

Migration of subdermal contraceptive implants into the pulmonary vasculature is a rare but increasingly recognised complication. Optimal management remains unclear, with options including conservative monitoring, endovascular retrieval or surgery. We report the case of a woman in her late 20s with a non-palpable Nexplanon implant, found within a segmental branch of the right lower lobe pulmonary artery. Following multidisciplinary discussion and patient counselling, surgical removal was performed via a mini-thoracotomy after initial video-assisted thoracoscopic surgery exploration. A targeted lung-sparing incision enabled device retrieval without lung resection. The postoperative course was uneventful apart from transient issues with pain management, and the patient was discharged on postoperative day 5. This case highlights a precision surgical approach to remove a pulmonary artery-embedded contraceptive implant without sacrificing lung parenchyma. It underscores the importance of shared decision-making and a tailored, multidisciplinary approach in managing rare device-related complications.

Authors

Institutions

Publication Details

Journal
BMJ Case Reports
Published
2025-12-01
DOI
https://doi.org/10.1136/bcr-2025-266348
Primary Topic
Reproductive Health and Contraception
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Pulmonary embolism of subdermal contraceptive implant: lung-sparing precision removal

Adam Peryt, Ibrahim T. Fazmin, Aman S. Coonar, Giuseppe Aresu
BMJ Case Reports
Reproductive Health and Contraception
article

Pulmonary embolism of subdermal contraceptive implant: lung-sparing precision removal

Adam Peryt, Ibrahim T. Fazmin, Aman S. Coonar, Giuseppe Aresu
article en

Abstract

Migration of subdermal contraceptive implants into the pulmonary vasculature is a rare but increasingly recognised complication. Optimal management remains unclear, with options including conservative monitoring, endovascular retrieval or surgery. We report the case of a woman in her late 20s with a non-palpable Nexplanon implant, found within a segmental branch of the right lower lobe pulmonary artery. Following multidisciplinary discussion and patient counselling, surgical removal was performed via a mini-thoracotomy after initial video-assisted thoracoscopic surgery exploration. A targeted lung-sparing incision enabled device retrieval without lung resection. The postoperative course was uneventful apart from transient issues with pain management, and the patient was discharged on postoperative day 5. This case highlights a precision surgical approach to remove a pulmonary artery-embedded contraceptive implant without sacrificing lung parenchyma. It underscores the importance of shared decision-making and a tailored, multidisciplinary approach in managing rare device-related complications.

BMJ Case ReportsVol. 18(12)
University of Cambridge (GB), Papworth Hospital NHS Foundation Trust (GB)
Openalex Percentile: Top 51%
Reproductive Health and Contraception
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Pulmonary embolism of subdermal contraceptive implant: lung-sparing precision removal — Adam Peryt, Ibrahim T. Fazmin, et al. · BMJ Case Reports (2025) | TGRS Research Map | TGRS