Efficient Whole-Brain Quantitative Magnetization Transfer Imaging at 3T Using Segmented EPI Readout with Variable Power Magnetization Transfer Pulses (EP-vpMT)

Quantitative magnetization transfer (qMT) imaging is sensitive to myelin-related macromolecular content and brain microstructure but is limited by long scan times. We present a fast, SAR-efficient qMT technique using a segmented echo-planar imaging readout with variable power MT preparation (EP-vpMT). EP-vpMT was implemented at 3T (1.5×1.5×4.0 mm³ voxels; 9 µL) using a 3D segmented EPI readout with modulated MT RF pulses to reduce SAR while preserving contrast. Pseudo bound pool fraction (pseudo-BPF) maps were obtained from healthy participants. Consistency with pseudo-BPF derived from conventional GRE-MT and repeatability was subject to Bland-Altman analysis. Multiple sclerosis (MS) patients were examined at 3T and at 7T (2.0 mm isotropic voxels; 8 µL) to explore feasibility for assessing tissue integrity and for application at ultra-high field. EP-vpMT achieved whole-brain qMT in 6 min 25 sec, reducing scan time by 76% compared to GRE-based qMT (26 min 20 sec) while maintaining similar SAR levels. Strong agreement was observed between methods, and test-retest reliability showed minimal bias with 95% limits of agreement within a clinically negligible range. In MS patients, EP-vpMT delineated lesions at 3T and at 7T. EP-vpMT enables fast qMT imaging at 3T with strong agreement with conventional methods. Its ability to detect MS lesions and to translate to ultra-high field MRI supports future use for assessing myelin-related macromolecular content.

Authors

Institutions

Publication Details

Journal
NeuroImage
Published
2025-12-03
DOI
https://doi.org/10.1016/j.neuroimage.2025.121630
Primary Topic
Advanced MRI Techniques and Applications
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Efficient Whole-Brain Quantitative Magnetization Transfer Imaging at 3T Using Segmented EPI Readout with Variable Power Magnetization Transfer Pulses (EP-vpMT)

Se‐Hong Oh, Sarah M. Planchon, Daniel Ontaneda, Ken Sakaie et al.
NeuroImage
Advanced MRI Techniques and Applications
article

Efficient Whole-Brain Quantitative Magnetization Transfer Imaging at 3T Using Segmented EPI Readout with Variable Power Magnetization Transfer Pulses (EP-vpMT)

Se‐Hong Oh, Sarah M. Planchon, Daniel Ontaneda, Ken Sakaie, Mark J. Lowe, Katherine Koenig, Stephen E. Jones, Devon Conway, Gawon Lee
article en

Abstract

Quantitative magnetization transfer (qMT) imaging is sensitive to myelin-related macromolecular content and brain microstructure but is limited by long scan times. We present a fast, SAR-efficient qMT technique using a segmented echo-planar imaging readout with variable power MT preparation (EP-vpMT). EP-vpMT was implemented at 3T (1.5×1.5×4.0 mm³ voxels; 9 µL) using a 3D segmented EPI readout with modulated MT RF pulses to reduce SAR while preserving contrast. Pseudo bound pool fraction (pseudo-BPF) maps were obtained from healthy participants. Consistency with pseudo-BPF derived from conventional GRE-MT and repeatability was subject to Bland-Altman analysis. Multiple sclerosis (MS) patients were examined at 3T and at 7T (2.0 mm isotropic voxels; 8 µL) to explore feasibility for assessing tissue integrity and for application at ultra-high field. EP-vpMT achieved whole-brain qMT in 6 min 25 sec, reducing scan time by 76% compared to GRE-based qMT (26 min 20 sec) while maintaining similar SAR levels. Strong agreement was observed between methods, and test-retest reliability showed minimal bias with 95% limits of agreement within a clinically negligible range. In MS patients, EP-vpMT delineated lesions at 3T and at 7T. EP-vpMT enables fast qMT imaging at 3T with strong agreement with conventional methods. Its ability to detect MS lesions and to translate to ultra-high field MRI supports future use for assessing myelin-related macromolecular content.

NeuroImageVol. 328
Cleveland Clinic (US), Hankuk University of Foreign Studies (KR)
Openalex Percentile: Top 47%
Advanced MRI Techniques and Applications
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.