School Renovation Impact on IAQ and Embodied Carbon: A Comparative Field Study with Statistical and LCA Insights

Indoor air quality (IAQ) in schools is directly linked to student health, comfort, and performance, while renovation strategies are increasingly assessed for their embodied carbon impacts alongside energy savings. However, little is known about how renovation affects both IAQ and embodied emissions in real school settings. This study hypothesized that renovation improves thermal stability but may not ensure compliance with IAQ standards, while introducing additional embodied carbon from new materials. To test this, two architecturally identical Lithuanian schools, one renovated, one non-renovated, were compared during the transition from heating to cooling season. IAQ monitoring focused on carbon dioxide (CO2), temperature, and relative humidity, and a life cycle assessment (LCA) was used to evaluate the additional embodied carbon of renovation materials, since energy-focused upgrades like insulation and new windows can improve indoor comfort but also increase material-related emissions. Results showed that renovation improved temperature stability and reduced sensitivity to outdoor conditions, but both schools frequently exceeded recommended CO2 thresholds during lessons. The LCA showed notable embodied carbon impacts from façade insulation and window replacement (A1-A3 stages), highlighting a trade-off between material use and comfort gains, though long-term operational savings may offset these initial emissions over the building service life. The results underline the importance of renovation that brings together thermal comfort and CO2 performance and embodied carbon reduction to create both healthy and sustainable learning environments.

Authors

Institutions

Publication Details

Journal
Buildings
Published
2025-11-28
DOI
https://doi.org/10.3390/buildings15234341
Primary Topic
Indoor Air Quality and Microbial Exposure
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

School Renovation Impact on IAQ and Embodied Carbon: A Comparative Field Study with Statistical and LCA Insights

Lina Šeduikytė, Paulius Vestfal
Buildings
Indoor Air Quality and Microbial Exposure
article

School Renovation Impact on IAQ and Embodied Carbon: A Comparative Field Study with Statistical and LCA Insights

Lina Šeduikytė, Paulius Vestfal
article en

Abstract

Indoor air quality (IAQ) in schools is directly linked to student health, comfort, and performance, while renovation strategies are increasingly assessed for their embodied carbon impacts alongside energy savings. However, little is known about how renovation affects both IAQ and embodied emissions in real school settings. This study hypothesized that renovation improves thermal stability but may not ensure compliance with IAQ standards, while introducing additional embodied carbon from new materials. To test this, two architecturally identical Lithuanian schools, one renovated, one non-renovated, were compared during the transition from heating to cooling season. IAQ monitoring focused on carbon dioxide (CO2), temperature, and relative humidity, and a life cycle assessment (LCA) was used to evaluate the additional embodied carbon of renovation materials, since energy-focused upgrades like insulation and new windows can improve indoor comfort but also increase material-related emissions. Results showed that renovation improved temperature stability and reduced sensitivity to outdoor conditions, but both schools frequently exceeded recommended CO2 thresholds during lessons. The LCA showed notable embodied carbon impacts from façade insulation and window replacement (A1-A3 stages), highlighting a trade-off between material use and comfort gains, though long-term operational savings may offset these initial emissions over the building service life. The results underline the importance of renovation that brings together thermal comfort and CO2 performance and embodied carbon reduction to create both healthy and sustainable learning environments.

BuildingsVol. 15(23)
Kaunas University of Technology (LT)
Openalex Percentile: Top 53%
Indoor Air Quality and Microbial Exposure
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

School Renovation Impact on IAQ and Embodied Carbon: A Comparative Field Study with Statistical and LCA Insights — Lina Šeduikytė, Paulius Vestfal · Buildings (2025) | TGRS Research Map | TGRS