A novel method for <i>in situ</i> Young’s modulus measurement of biological tissues based on rebound process

Accurate quantification of Young's modulus in biological tissues enhances clinical accuracy in disease diagnosis, therapy, and prevention. Nevertheless, real-time, intraoperative measurement of Young's modulus in organs remains technically challenging. We propose a novel in situ tissue elasticity assessment method based on the principles of the rebound process, where a magnetized probe is used to impact the target tissue, and Young's modulus is calculated based on how quickly the probe rebounds. The proposed method was validated through a theoretical mechanical model and simulation. The measurement accuracy was verified by replicated measurements across different specimens. A portable handheld device was then developed and deployed for clinical feasibility validation in live animal models. Results demonstrate that the proposed method delivers accurate and reliable measurements. The proposed system offers a novel solution for Young's modulus measurement, which can be used for intraoperative conditions such as lesion assessment during hepatectomy and breast-conserving surgery.

Authors

Institutions

Publication Details

Journal
Review of Scientific Instruments
Published
2025-12-01
DOI
https://doi.org/10.1063/5.0300992
Primary Topic
Ultrasound Imaging and Elastography
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

A novel method for in situ Young’s modulus measurement of biological tissues based on rebound process

Y G Chen, Fu Ji, X.P. Cui
Review of Scientific Instruments
Ultrasound Imaging and Elastography
article

A novel method for in situ Young’s modulus measurement of biological tissues based on rebound process

Y G Chen, Fu Ji, X.P. Cui
article en

Abstract

Accurate quantification of Young's modulus in biological tissues enhances clinical accuracy in disease diagnosis, therapy, and prevention. Nevertheless, real-time, intraoperative measurement of Young's modulus in organs remains technically challenging. We propose a novel in situ tissue elasticity assessment method based on the principles of the rebound process, where a magnetized probe is used to impact the target tissue, and Young's modulus is calculated based on how quickly the probe rebounds. The proposed method was validated through a theoretical mechanical model and simulation. The measurement accuracy was verified by replicated measurements across different specimens. A portable handheld device was then developed and deployed for clinical feasibility validation in live animal models. Results demonstrate that the proposed method delivers accurate and reliable measurements. The proposed system offers a novel solution for Young's modulus measurement, which can be used for intraoperative conditions such as lesion assessment during hepatectomy and breast-conserving surgery.

Review of Scientific InstrumentsVol. 96(12)
Zhejiang Sci-Tech University (CN), Peking University (CN)
Openalex Percentile: Top 47%
Ultrasound Imaging and Elastography
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.