Behaviour of heated steel beams with lateral and axial restraint in steel-timber hybrid structures

Amidst the climate emergency and ambitions to decarbonise the built environment, hybrid systems consisting of a steel structural frame supporting cross-laminated timber floors have emerged as a new paradigm in sustainable construction. While this form of hybridisation is beneficial in many ways, it also presents certain challenges, particularly regarding its structural performance in fire. A critical concern in fire is the risk of lateral-torsional buckling of the steel beams connected to the timber slabs with self-tapping screws, which goes beyond the scope of current design guidance. Using a numerical approach, this study has developed finite element modelling capacity to investigate the thermo-mechanical response of a 9 m unprotected steel beam with screws at 250 mm spacing under various levels of lateral restraint from the screws and axial restraint from the end connections. The imposed heating regimes have also explored the influence of the temperature on the compression flanges of the steel beam. When axial restraint is present, indicating a realistic support condition in fire, the beam initially behaves similarly to a corresponding fully laterally restrained beam. This response continues until the first screw fails in the midspan region, which eventually triggers instability by lateral-torsional buckling. The results highlight the significance of lateral restraint in enhancing the fire performance of steel-timber hybrid structures. However, it is not realistic to assume a full lateral restraint condition in fire design. • Provides new insights into the fire performance of steel-timber hybrid structures. • Screws provide some lateral restraint against lateral-torsional buckling in fire. • Unrealistic to assume steel beams as fully laterally restrained in fire. • Designing beams as laterally unrestrained in fire is conservative. • Lateral-torsional buckling affects the development of catenary action.

Authors

Institutions

Publication Details

Journal
Engineering Structures
Published
2025-12-03
DOI
https://doi.org/10.1016/j.engstruct.2025.121887
Citations
1
Primary Topic
Structural Load-Bearing Analysis
Type
article
Field-Weighted Citation Impact
0.95
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Behaviour of heated steel beams with lateral and axial restraint in steel-timber hybrid structures

Buick Davison, Ian Burgess, Danny Hopkin, Martyn S. McLaggan et al.
1 citations
Engineering Structures
Structural Load-Bearing Analysis
0.95
article

Behaviour of heated steel beams with lateral and axial restraint in steel-timber hybrid structures

Buick Davison, Ian Burgess, Danny Hopkin, Martyn S. McLaggan, Shan‐Shan Huang, Aatish Jeebodh
article en
1 citations

Abstract

Amidst the climate emergency and ambitions to decarbonise the built environment, hybrid systems consisting of a steel structural frame supporting cross-laminated timber floors have emerged as a new paradigm in sustainable construction. While this form of hybridisation is beneficial in many ways, it also presents certain challenges, particularly regarding its structural performance in fire. A critical concern in fire is the risk of lateral-torsional buckling of the steel beams connected to the timber slabs with self-tapping screws, which goes beyond the scope of current design guidance. Using a numerical approach, this study has developed finite element modelling capacity to investigate the thermo-mechanical response of a 9 m unprotected steel beam with screws at 250 mm spacing under various levels of lateral restraint from the screws and axial restraint from the end connections. The imposed heating regimes have also explored the influence of the temperature on the compression flanges of the steel beam. When axial restraint is present, indicating a realistic support condition in fire, the beam initially behaves similarly to a corresponding fully laterally restrained beam. This response continues until the first screw fails in the midspan region, which eventually triggers instability by lateral-torsional buckling. The results highlight the significance of lateral restraint in enhancing the fire performance of steel-timber hybrid structures. However, it is not realistic to assume a full lateral restraint condition in fire design. • Provides new insights into the fire performance of steel-timber hybrid structures. • Screws provide some lateral restraint against lateral-torsional buckling in fire. • Unrealistic to assume steel beams as fully laterally restrained in fire. • Designing beams as laterally unrestrained in fire is conservative. • Lateral-torsional buckling affects the development of catenary action.

Engineering StructuresVol. 349
Oxford Computer Consultants (United Kingdom) (GB), University of Sheffield (GB)
Openalex Percentile: Top 19%
Structural Load-Bearing Analysis
0.95
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.