$^{60}\rm{Co}$ $\gamma$ Irradiation of a CMS CROC v2 to 1.6 Grad
This paper reports the irradiation of the production version of the readout chip for the CMS HL-LHC pixel detector, CROC~v2, to 1.6~Grad using $\gamma$s from a $^{60}$Co source at Sandia National Laboratory. The CROC~v2 was kept powered, configured, and maintained as close as possible to its nominal operating temperature of -20~$^{\rm o}$C during irradiation. Internal chip voltages, pixel response, and diagnostic ring oscillators were continuously monitored, and thresholds were optimized frequently. The CROC~v2 performed according to specifications at 1.6~Grad. Where available, these results will be compared with those for this and earlier iterations of the RD53 readout chip irradiated to a few Grad with lower-energy X-ray sources.
Authors
- Stephen J. Wagner (ORCID: https://orcid.org/0000-0001-5720-4862)
- Karl J. Friston
Publication Details
- Published
- 2025-12-03
- DOI
- https://doi.org/10.22323/1.513.0016
- Primary Topic
- Particle Detector Development and Performance
- Type
- article
- Field-Weighted Citation Impact
- 0.00
Funders
- National Science Foundation
- U.S. Department of Energy
- Oak Ridge National Laboratory
- Sandia National Laboratories