Detailed investigation of Acceptor Removal in LGAD

A Low Gain Avalanche Diode (LGAD) sensor is developed for high-precision timing measurements. For applications of LGAD detectors in high-energy and high-luminosity hadron collider experiments, the detector must exhibit sufficient radiation tolerance against both Total Ionizing Dose (TID) and Non-Ionizing Energy Loss (NIEL) effects. In previous studies, the oxygen concentration in the sensor has been suggested to play a significant role in radiation-induced degradation, as the formation of $\mathrm{B_iO_i}$ complexes was considered a major cause of acceptor removal in the gain layer. In this study, we developed radiation-hard LGAD prototypes with reduced oxygen concentration using process improvements and the Partially Activated Boron method. Radiation tolerance was evaluated through depletion voltage and timing resolution measurements after irradiation with 45 MeV protons. The results show that the radiation tolerance of LGAD does not depend significantly on the oxygen concentration, suggesting that $\mathrm{B_iO_i}$ defects are not the dominant cause of acceptor removal in the gain layer.}

Authors

Publication Details

Published
2025-12-03
DOI
https://doi.org/10.22323/1.513.0021
Primary Topic
Particle Detector Development and Performance
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Detailed investigation of Acceptor Removal in LGAD

Yua Murayama, Sayuka Kita, Koji Sato, Koji Nakamura et al.
Particle Detector Development and Performance
article

Detailed investigation of Acceptor Removal in LGAD

Yua Murayama, Sayuka Kita, Koji Sato, Koji Nakamura, Issei Horikoshi, Tomoka Imamura
article en

Abstract

A Low Gain Avalanche Diode (LGAD) sensor is developed for high-precision timing measurements. For applications of LGAD detectors in high-energy and high-luminosity hadron collider experiments, the detector must exhibit sufficient radiation tolerance against both Total Ionizing Dose (TID) and Non-Ionizing Energy Loss (NIEL) effects. In previous studies, the oxygen concentration in the sensor has been suggested to play a significant role in radiation-induced degradation, as the formation of $\mathrm{B_iO_i}$ complexes was considered a major cause of acceptor removal in the gain layer. In this study, we developed radiation-hard LGAD prototypes with reduced oxygen concentration using process improvements and the Partially Activated Boron method. Radiation tolerance was evaluated through depletion voltage and timing resolution measurements after irradiation with 45 MeV protons. The results show that the radiation tolerance of LGAD does not depend significantly on the oxygen concentration, suggesting that $\mathrm{B_iO_i}$ defects are not the dominant cause of acceptor removal in the gain layer.}

Ministry of Education, Culture, Sports, Science and Technology, High Energy Accelerator Research Organization, High Energy Physics, Fermilab
Openalex Percentile: Top 83%
Particle Detector Development and Performance
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Detailed investigation of Acceptor Removal in LGAD — Yua Murayama, Sayuka Kita, et al. · (2025) | TGRS Research Map | TGRS