Pixel Core Column Issue in the ATLAS Inner Tracker modules

Pixel modules for the ATLAS ITk Pixel detector upgrade are currently undergoing production and quality control. During pre-production electrical testing, a recurring front-end chip communication issue was observed that could be bypassed by selectively disabling pixel core columns within the affected chips. The issue, designated as the "core column issue," has been documented across a large number of both ITkPix v1.1 and v2 modules. Since disabling a core column significantly reduces the number of operation pixels in a module, the prevalence of this failure could substantially impact ITk tracking performance. The erratic behavior of the core column has led to difficulties in diagnosing its underlying cause. However, recent progress in visual inspection, combined with statistical analysis of production database records, points towards possible causes of the issue. This contribution highlights the discovery of, attempts to mitigate, production testing strategies, and current hypotheses of the core column issue.

Authors

Publication Details

Published
2025-12-03
DOI
https://doi.org/10.22323/1.513.0014
Primary Topic
Particle Detector Development and Performance
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Pixel Core Column Issue in the ATLAS Inner Tracker modules

M. Marjanović, J. R. Pater, C. M. Buttar, J. Christiansen et al.
Particle Detector Development and Performance
article

Pixel Core Column Issue in the ATLAS Inner Tracker modules

M. Marjanović, J. R. Pater, C. M. Buttar, J. Christiansen, K. Nakamura, Md. Arif Abdulla Samy, F. Loddo, Y. Dieter, Luke Cunningham, R. L. Bates, J. Metcalfe, A. Sharma, S. Hirose, E. A. Thompson, Maximilian Schuessler, A. Korn, F. Crescioli, L. Meng, D. W. Kim, T. Heim, M. Backhaus, H. Pernegger, F. Huegging, G. Calderini, Ruiqing Han
article en

Abstract

Pixel modules for the ATLAS ITk Pixel detector upgrade are currently undergoing production and quality control. During pre-production electrical testing, a recurring front-end chip communication issue was observed that could be bypassed by selectively disabling pixel core columns within the affected chips. The issue, designated as the "core column issue," has been documented across a large number of both ITkPix v1.1 and v2 modules. Since disabling a core column significantly reduces the number of operation pixels in a module, the prevalence of this failure could substantially impact ITk tracking performance. The erratic behavior of the core column has led to difficulties in diagnosing its underlying cause. However, recent progress in visual inspection, combined with statistical analysis of production database records, points towards possible causes of the issue. This contribution highlights the discovery of, attempts to mitigate, production testing strategies, and current hypotheses of the core column issue.

Openalex Percentile: Top 83%
Particle Detector Development and Performance
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.