Evaluation of Thermal Retrofit Variants for Facades in High-Rise Large-Panel Residential Buildings: Impact on Energy Demand Using the BESM Model

Abstract This article examines the effectiveness of secondary thermal retrofitting in high-rise buildings constructed using large-panel technology and presents a model for evaluating the efficiency of facade modernisation and aesthetic enhancement methods, with particular emphasis on their energy performance. Three retrofit variants were analysed: increased glazing of balconies, aluminium-clad balcony facades, and a fully glazed facade. Calculations were performed using Audytor software by Sankom, based on an energy audit and in-situ measurements, taking into account the U -value [W/(m 2 ·K)], annual energy demand EHV [kWh/m 2 ·year], cost C [€/m 2 ], and carbon footprint eCO 2 [kgCO 2 /(m 2 ·year)]. The results show that Variant 2 (V2) achieves the greatest energy consumption reduction (32.1%), while Variant 1 (V1) provides the best insulation performance ( U = 0.149 W/m 2 K) and the highest BESM index (1.109). Despite its higher cost (155 €/m²), V2 significantly improves both the building’s energy efficiency and aesthetics. Optimising thermal retrofit methods is a key factor in adapting large-panel buildings to contemporary standards and enhancing residents’ quality of life.

Authors

Institutions

Publication Details

Journal
Środowisko Mieszkaniowe
Published
2025-11-28
DOI
https://doi.org/10.2478/he-2025-0030
Primary Topic
Building Energy and Comfort Optimization
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Evaluation of Thermal Retrofit Variants for Facades in High-Rise Large-Panel Residential Buildings: Impact on Energy Demand Using the BESM Model

Dariusz Gaweł, Łukasz Guz, Natalia Jakubiak
Środowisko Mieszkaniowe
Building Energy and Comfort Optimization
article

Evaluation of Thermal Retrofit Variants for Facades in High-Rise Large-Panel Residential Buildings: Impact on Energy Demand Using the BESM Model

Dariusz Gaweł, Łukasz Guz, Natalia Jakubiak
article en

Abstract

Abstract This article examines the effectiveness of secondary thermal retrofitting in high-rise buildings constructed using large-panel technology and presents a model for evaluating the efficiency of facade modernisation and aesthetic enhancement methods, with particular emphasis on their energy performance. Three retrofit variants were analysed: increased glazing of balconies, aluminium-clad balcony facades, and a fully glazed facade. Calculations were performed using Audytor software by Sankom, based on an energy audit and in-situ measurements, taking into account the U -value [W/(m 2 ·K)], annual energy demand EHV [kWh/m 2 ·year], cost C [€/m 2 ], and carbon footprint eCO 2 [kgCO 2 /(m 2 ·year)]. The results show that Variant 2 (V2) achieves the greatest energy consumption reduction (32.1%), while Variant 1 (V1) provides the best insulation performance ( U = 0.149 W/m 2 K) and the highest BESM index (1.109). Despite its higher cost (155 €/m²), V2 significantly improves both the building’s energy efficiency and aesthetics. Optimising thermal retrofit methods is a key factor in adapting large-panel buildings to contemporary standards and enhancing residents’ quality of life.

Środowisko MieszkanioweVol. 53(4)
Lublin University of Technology (PL)
Openalex Percentile: Top 59%
Building Energy and Comfort Optimization
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.