Real‐Time In Vivo Monitoring of Anastomotic Intestinal Ischemia Using Implantable Resorbable Organic Sensors

Anastomotic failure remains one of the most severe complications in gastrointestinal surgery. Despite continuous advancements in stapler technologies and surgical techniques, it continues to be a leading cause of postoperative morbidity and mortality. It contributes substantially to prolonged hospitalization and increased healthcare expenditures. Currently, diagnosis is based on secondary systemic signs, such as inflammatory response or changes in drain fluid, followed by a multimodal diagnostic approach. However, reliable early detection of local alterations is still lacking. Here, the implantation of a bioresorbable is investigated, intra-anastomotically placed sensor device. By performing real-time intra-anastomotic bioimpedance measurements, ischemia-related changes are identified at an early, potentially reversible stage, prior to the onset of clinical or systemic manifestations. Furthermore, the sensor device offers the potential for future integration of pattern-recognition algorithms and the possibility of direct measurement of different markers in the anastomotic microenvironment.

Authors

Institutions

Publication Details

Journal
Advanced Science
Published
2025-12-03
DOI
https://doi.org/10.1002/advs.202514507
Citations
1
Primary Topic
Colorectal Cancer Surgical Treatments
Type
article
Field-Weighted Citation Impact
1.05
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Real‐Time In Vivo Monitoring of Anastomotic Intestinal Ischemia Using Implantable Resorbable Organic Sensors

Karl Leo, Richard Kantelberg, Daniel C. Wahl, Eberhard Grambow et al.
1 citations
Advanced Science
Colorectal Cancer Surgical Treatments
1.05
article

Real‐Time In Vivo Monitoring of Anastomotic Intestinal Ischemia Using Implantable Resorbable Organic Sensors

Karl Leo, Richard Kantelberg, Daniel C. Wahl, Eberhard Grambow, Jutta Henne, Amelie Zitzmann, Finn Jaekel, Hans Kleemann, Jochen Hampe, Brigitte Vollmar, Sebastian Hinz, Clemens Schafmayer, Daniel C. Freund
article en
1 citations

Abstract

Anastomotic failure remains one of the most severe complications in gastrointestinal surgery. Despite continuous advancements in stapler technologies and surgical techniques, it continues to be a leading cause of postoperative morbidity and mortality. It contributes substantially to prolonged hospitalization and increased healthcare expenditures. Currently, diagnosis is based on secondary systemic signs, such as inflammatory response or changes in drain fluid, followed by a multimodal diagnostic approach. However, reliable early detection of local alterations is still lacking. Here, the implantation of a bioresorbable is investigated, intra-anastomotically placed sensor device. By performing real-time intra-anastomotic bioimpedance measurements, ischemia-related changes are identified at an early, potentially reversible stage, prior to the onset of clinical or systemic manifestations. Furthermore, the sensor device offers the potential for future integration of pattern-recognition algorithms and the possibility of direct measurement of different markers in the anastomotic microenvironment.

Advanced ScienceVol. 13(16)
Universitätsmedizin Göttingen (DE), University Hospital Carl Gustav Carus (DE), University of Rostock (DE), University of Göttingen (DE), Technische Universität Dresden (DE)
Openalex Percentile: Top 15%
Colorectal Cancer Surgical Treatments
1.05
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.