A Method for Rapid and Precise Triple Oxygen Isotope Measurements via High-Temperature Conversion to CO Followed by Nickel-Catalyzed CO to CO <sub>2</sub> Conversion and Laser Spectroscopy

Triple oxygen isotopic compositions (<sup>16</sup>O, <sup>17</sup>O, <sup>18</sup>O) have conventionally been measured via isotope ratio mass spectrometry using O<sub>2</sub> as an analyte. Conversion of sample oxygen to O<sub>2</sub> typically utilizes fluorination chemistry or catalytic equilibration between CO<sub>2</sub> and O<sub>2</sub>. Recently, laser spectroscopy has become a viable alternative for triple oxygen isotope (Δ'<sup>17</sup>O) measurements due to its ease and rapid throughput. Laser spectrometers are currently available for Δ'<sup>17</sup>O analysis of either H<sub>2</sub>O or CO<sub>2</sub> as the analyte gas. So far, these instruments have been used to measure Δ'<sup>17</sup>O of water, carbonate (CO<sub>2</sub> liberated by acid digestion), and atmospheric CO<sub>2</sub> samples. We present a new method for high-precision Δ'<sup>17</sup>O analysis of CO<sub>2</sub> via tunable infrared laser direct absorption spectroscopy that is compatible with a wider range of geochemically important materials. This approach involves converting sample oxygen to CO<sub>2</sub> in two steps. First, the sample oxygen is liberated and reduced to CO by high-temperature conversion at 1450 °C in the presence of excess elemental carbon. Then, CO is catalytically converted to CO<sub>2</sub> over hot nickel at 350 °C. The conversion process is rapid (10 to 30 min) and quantitative. Spectroscopic Δ'<sup>17</sup>O analysis of the resulting CO<sub>2</sub> takes approximately 45 min. By measuring several oxygen isotope standards, we demonstrate that the method is precise (1σ = 12 per meg for procedural replicates) and accurate (within 11 per meg of previously reported values). The method can be applied to most pyrolytic materials where quantitative oxygen conversion is attainable, such as sulfate, phosphate, nitrate, and oxide minerals, water, and organic molecules.

Authors

Institutions

Publication Details

Journal
Analytical Chemistry
Published
2025-12-03
DOI
https://doi.org/10.1021/acs.analchem.5c04851
Citations
1
Primary Topic
Isotope Analysis in Ecology
Type
article
Field-Weighted Citation Impact
1.72
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

A Method for Rapid and Precise Triple Oxygen Isotope Measurements via High-Temperature Conversion to CO Followed by Nickel-Catalyzed CO to CO 2 Conversion and Laser Spectroscopy

David D. Nelson, Daniel A. Stolper, Nicholas M. Ellis, Todd E. Dawson et al.
1 citations
Analytical Chemistry
Isotope Analysis in Ecology
1.72
article

A Method for Rapid and Precise Triple Oxygen Isotope Measurements via High-Temperature Conversion to CO Followed by Nickel-Catalyzed CO to CO 2 Conversion and Laser Spectroscopy

David D. Nelson, Daniel A. Stolper, Nicholas M. Ellis, Todd E. Dawson, Scott C. Herndon, Richard Wehr, Wenbo Yang, Kian Kafaie
article en
1 citations

Abstract

Triple oxygen isotopic compositions (<sup>16</sup>O, <sup>17</sup>O, <sup>18</sup>O) have conventionally been measured via isotope ratio mass spectrometry using O<sub>2</sub> as an analyte. Conversion of sample oxygen to O<sub>2</sub> typically utilizes fluorination chemistry or catalytic equilibration between CO<sub>2</sub> and O<sub>2</sub>. Recently, laser spectroscopy has become a viable alternative for triple oxygen isotope (Δ'<sup>17</sup>O) measurements due to its ease and rapid throughput. Laser spectrometers are currently available for Δ'<sup>17</sup>O analysis of either H<sub>2</sub>O or CO<sub>2</sub> as the analyte gas. So far, these instruments have been used to measure Δ'<sup>17</sup>O of water, carbonate (CO<sub>2</sub> liberated by acid digestion), and atmospheric CO<sub>2</sub> samples. We present a new method for high-precision Δ'<sup>17</sup>O analysis of CO<sub>2</sub> via tunable infrared laser direct absorption spectroscopy that is compatible with a wider range of geochemically important materials. This approach involves converting sample oxygen to CO<sub>2</sub> in two steps. First, the sample oxygen is liberated and reduced to CO by high-temperature conversion at 1450 °C in the presence of excess elemental carbon. Then, CO is catalytically converted to CO<sub>2</sub> over hot nickel at 350 °C. The conversion process is rapid (10 to 30 min) and quantitative. Spectroscopic Δ'<sup>17</sup>O analysis of the resulting CO<sub>2</sub> takes approximately 45 min. By measuring several oxygen isotope standards, we demonstrate that the method is precise (1σ = 12 per meg for procedural replicates) and accurate (within 11 per meg of previously reported values). The method can be applied to most pyrolytic materials where quantitative oxygen conversion is attainable, such as sulfate, phosphate, nitrate, and oxide minerals, water, and organic molecules.

Analytical ChemistryVol. 97(50)
Planetary Science Institute (US), Lawrence Berkeley National Laboratory (US), Oxford Policy Management (GB), University of California System (US), Aerodyne Research (US), Centre de Géosciences (FR), The Stables (GB), University of California, Berkeley (US)
Openalex Percentile: Top 12%
Isotope Analysis in Ecology
1.72
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.