Plasma‐Based NH <sub>3</sub> Cracking: A Better Insight in the Performance by Chemical Kinetics Modeling

This study examines performance characteristics of (warm-)plasma-based NH<sub>3</sub> cracking using a detailed plasma chemical kinetics model across a wide range of gas temperatures (T<sub>g</sub> = 1000-6000 K) and electron temperatures (T<sub>e</sub> = 0-3.5 eV, i.e., 0-40,000 K). NH<sub>3</sub> conversion increases with both temperatures, but the T<sub>g</sub>-dependence flattens near full conversion. Pure thermal cracking reaches full conversion at 2300 K and 10 ms, while plasma achieves full conversion at T<sub>e</sub> > 2.75 eV for all T<sub>g</sub>, even the lowest T<sub>g</sub> values investigated. At T<sub>g</sub> < 2700 K, high T<sub>e</sub> dramatically reduces the time for full conversion, for example, from thousands of years (thermal) to milliseconds (plasma) at T<sub>g</sub> = 1100 K, while differences vanish at T<sub>g</sub> > 2700 K. Product composition follows thermal equilibrium, showing negligible T<sub>e</sub> influence. Importantly, we also suggest strategies for performance improvement. The best energy cost for typical warm plasmas with continuous power is predicted to be 197 kJ/mol-NH<sub>3</sub> at 2500 K, where thermal pathways dominate. Reducing vibrational energy losses suggests potential improvement at T<sub>g</sub> ≈1500 K, predicting an energy cost of 157 kJ/mol-NH<sub>3</sub>, for so-called "plasma-initialized" thermal cracking. Further reduction in energy cost should be feasible via heat recovery. Overall, our model shows that plasma cracking offers rapid NH<sub>3</sub> conversion with reasonable energy cost.

Authors

Institutions

Publication Details

Journal
ChemSusChem
Published
2025-12-02
DOI
https://doi.org/10.1002/cssc.202501984
Primary Topic
Plasma Diagnostics and Applications
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Plasma‐Based NH 3 Cracking: A Better Insight in the Performance by Chemical Kinetics Modeling

Stein Maerivoet, Seunghwan Bang, Ivan Tsonev, Annemie Bogaerts et al.
ChemSusChem
Plasma Diagnostics and Applications
article

Plasma‐Based NH 3 Cracking: A Better Insight in the Performance by Chemical Kinetics Modeling

Stein Maerivoet, Seunghwan Bang, Ivan Tsonev, Annemie Bogaerts, François Reniers
article en

Abstract

This study examines performance characteristics of (warm-)plasma-based NH<sub>3</sub> cracking using a detailed plasma chemical kinetics model across a wide range of gas temperatures (T<sub>g</sub> = 1000-6000 K) and electron temperatures (T<sub>e</sub> = 0-3.5 eV, i.e., 0-40,000 K). NH<sub>3</sub> conversion increases with both temperatures, but the T<sub>g</sub>-dependence flattens near full conversion. Pure thermal cracking reaches full conversion at 2300 K and 10 ms, while plasma achieves full conversion at T<sub>e</sub> > 2.75 eV for all T<sub>g</sub>, even the lowest T<sub>g</sub> values investigated. At T<sub>g</sub> < 2700 K, high T<sub>e</sub> dramatically reduces the time for full conversion, for example, from thousands of years (thermal) to milliseconds (plasma) at T<sub>g</sub> = 1100 K, while differences vanish at T<sub>g</sub> > 2700 K. Product composition follows thermal equilibrium, showing negligible T<sub>e</sub> influence. Importantly, we also suggest strategies for performance improvement. The best energy cost for typical warm plasmas with continuous power is predicted to be 197 kJ/mol-NH<sub>3</sub> at 2500 K, where thermal pathways dominate. Reducing vibrational energy losses suggests potential improvement at T<sub>g</sub> ≈1500 K, predicting an energy cost of 157 kJ/mol-NH<sub>3</sub>, for so-called "plasma-initialized" thermal cracking. Further reduction in energy cost should be feasible via heat recovery. Overall, our model shows that plasma cracking offers rapid NH<sub>3</sub> conversion with reasonable energy cost.

ChemSusChemVol. 19(7)
Université Libre de Bruxelles (BE), University of Antwerp (BE)
Vlaams Supercomputer Centrum, European Commission, Fonds De La Recherche Scientifique - FNRS, Fonds Wetenschappelijk Onderzoek, Universiteit Antwerpen, Vlaamse regering
Openalex Percentile: Top 62%
Plasma Diagnostics and Applications
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.