Reply to comment on impact of deep learning on CT-based organ-at-risk delineation for flank irradiation in paediatric renal tumours: A SIOP-RTSG radiotherapy committee

We appreciate the commentary from Saad et al., which offers an opportunity to clarify key methodological and clinical aspects of our study assessing the impact of deep learning-based CT auto-contouring for organ-at-risk delineation in paediatric flank irradiation for renal tumours. First, the annotation protocol was provided in the original Supplementary Materials, and additional delineation instructions followed established SIOP-RTSG standards. Second, as already mentioned in the manuscript discussion, we acknowledge the inherent bias associated with STAPLE consensus contours, and we addressed this by including an additional single-expert reference in our evaluation. Third, although dose analysis can provide valuable clinical insights, it is not essential at this stage, as geometric evaluation remains the main benchmark for validating auto-contouring performance. Fourth, while uncertainty quantification is a promising research direction, our study was designed to reflect current clinical practice, where uncertainty-aware segmentation has not yet been integrated into routine auto-segmentation systems. Finally, we recognize that our controlled workshop environment does not fully reflect real-world clinical workflows, a limitation already discussed in our original manuscript. We hope these clarifications foster a balanced understanding of our work and support ongoing efforts toward the safe and effective clinical adoption of AI-assisted contouring in paediatric radiotherapy.

Authors

Institutions

Publication Details

Journal
Clinical and Translational Radiation Oncology
Published
2025-12-03
DOI
https://doi.org/10.1016/j.ctro.2025.101087
Primary Topic
Advanced Radiotherapy Techniques
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Reply to comment on impact of deep learning on CT-based organ-at-risk delineation for flank irradiation in paediatric renal tumours: A SIOP-RTSG radiotherapy committee

Semi Harrabi, Matteo Maspero, Britta Weber, Remus Stoica et al.
Clinical and Translational Radiation Oncology
Advanced Radiotherapy Techniques
article

Reply to comment on impact of deep learning on CT-based organ-at-risk delineation for flank irradiation in paediatric renal tumours: A SIOP-RTSG radiotherapy committee

Semi Harrabi, Matteo Maspero, Britta Weber, Remus Stoica, Emmanuel Jouglar, Marry M. van den Heuvel‐Eibrink, Mianyong Ding, Henriette Magelssen, Simonetta Saldi, Karen Van Beek, Patrick Melchior, Terri S. Spencer, Tom Boterberg, Geert O. Janssens, Sabina Vennarini
article en

Abstract

We appreciate the commentary from Saad et al., which offers an opportunity to clarify key methodological and clinical aspects of our study assessing the impact of deep learning-based CT auto-contouring for organ-at-risk delineation in paediatric flank irradiation for renal tumours. First, the annotation protocol was provided in the original Supplementary Materials, and additional delineation instructions followed established SIOP-RTSG standards. Second, as already mentioned in the manuscript discussion, we acknowledge the inherent bias associated with STAPLE consensus contours, and we addressed this by including an additional single-expert reference in our evaluation. Third, although dose analysis can provide valuable clinical insights, it is not essential at this stage, as geometric evaluation remains the main benchmark for validating auto-contouring performance. Fourth, while uncertainty quantification is a promising research direction, our study was designed to reflect current clinical practice, where uncertainty-aware segmentation has not yet been integrated into routine auto-segmentation systems. Finally, we recognize that our controlled workshop environment does not fully reflect real-world clinical workflows, a limitation already discussed in our original manuscript. We hope these clarifications foster a balanced understanding of our work and support ongoing efforts toward the safe and effective clinical adoption of AI-assisted contouring in paediatric radiotherapy.

Clinical and Translational Radiation OncologyVol. 57
Oslo University Hospital (NO), Heidelberg University (DE), Université Paris Sciences et Lettres (FR), Ghent University Hospital (BE), University Hospital Heidelberg (DE), University Medical Center Utrecht (NL), Spitalului Clinic de Urgență pentru Copii Maria Sklodowska Curie (RO), Heidelberger Institut für Radioonkologie (DE), Ospedale Santa Maria (IT), Princess Máxima Center (NL), Cancer Genomics Centre (NL), Centre for Cosmology and Particle Physics Phenomenology (DK), Fondazione IRCCS Istituto Nazionale dei Tumori (IT), Wilhelmina Children's Hospital (NL), Saarland University (DE), KU Leuven (BE)
Openalex Percentile: Top 53%
Advanced Radiotherapy Techniques
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.