Image-based geometry calibration for a double-tomograph

Abstract Fast tomographic acquisitions are essential to study time-dependent and rapid phenomena in materials science, e.g. viscoelasticity or crack propagation. Acquisition time can be halved by employing two x-ray sources and detectors, provided they can be switched interchangeably. This work discusses the reconstruction of 3D volumes using data acquired simultaneously from two crossed-line laboratory tomographs. For this, geometrical parameters are proposed and their sensitivity is tested, allowing to discard less significant parameters. The selected parameters are then calibrated solely from the acquired projections of the object, by minimizing the difference between the reprojected volume and the experimental data. A gypsum sample is used as a model material, and three acquisition speed configurations—ranging from 20 s to 500 s—are tested to evaluate the effect of noise. The proposed procedure was shown to be robust even under noisier acquisition conditions. This methodology is believed to be an important step towards in-situ mechanical tests to be analyzed with projection-based techniques, with potentially two- to three-orders-of-magnitude increase in acquisition rates.

Authors

Institutions

Publication Details

Journal
Measurement Science and Technology
Published
2025-12-02
DOI
https://doi.org/10.1088/1361-6501/ae26a4
Primary Topic
Optical measurement and interference techniques
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Image-based geometry calibration for a double-tomograph

Clément Jailin, Éric Maire, Stéphane Roux, R. Vargas et al.
Measurement Science and Technology
Optical measurement and interference techniques
article

Image-based geometry calibration for a double-tomograph

Clément Jailin, Éric Maire, Stéphane Roux, R. Vargas, Joël Lachambre, Jérôme Adrien, Viktor Kosin
article en

Abstract

Abstract Fast tomographic acquisitions are essential to study time-dependent and rapid phenomena in materials science, e.g. viscoelasticity or crack propagation. Acquisition time can be halved by employing two x-ray sources and detectors, provided they can be switched interchangeably. This work discusses the reconstruction of 3D volumes using data acquired simultaneously from two crossed-line laboratory tomographs. For this, geometrical parameters are proposed and their sensitivity is tested, allowing to discard less significant parameters. The selected parameters are then calibrated solely from the acquired projections of the object, by minimizing the difference between the reprojected volume and the experimental data. A gypsum sample is used as a model material, and three acquisition speed configurations—ranging from 20 s to 500 s—are tested to evaluate the effect of noise. The proposed procedure was shown to be robust even under noisier acquisition conditions. This methodology is believed to be an important step towards in-situ mechanical tests to be analyzed with projection-based techniques, with potentially two- to three-orders-of-magnitude increase in acquisition rates.

Measurement Science and TechnologyVol. 37(1)
Leibniz University Hannover (DE), Université de Lyon (FR), Matériaux Ingénierie et Science (FR), Laboratoire de Mécanique des Contacts et des Structures (FR), Laboratoire de Mécanique Paris-Saclay (FR)
Openalex Percentile: Top 61%
Optical measurement and interference techniques
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.