A low-power magnetic levitation capsule robot system based on permanent magnets-electromagnetic coils array

Magnetic levitation capsule robots show great promise for gastric disease diagnosis due to their non-invasive nature and low infection risk. To reduce electromagnetic coils’ power consumption and minimize the device size, this study proposes a modified magnetic levitation capsule robot system based on a commercial magnetic levitation device. Symmetrically distributed permanent magnets array provide the main levitation force, while electromagnetic coils’ array only provide horizontal restoring forces, significantly reducing power consumption. Through a bottom-mounted design, the entire apparatus is positioned beneath the hospital bed, improving clinical safety and convenience. Addressing the weakened Hall sensor signals caused by the reduced size of the capsule robot (levitating permanent magnet), we established an accurate magnetic field model, analyzed the interaction forces between the stator and capsule robot, developed a magnetic field-displacement measurement platform to precisely determine the relationship between effective signals detected by Hall sensors and capsule robot displacement, and quantified electromagnetic coils’ interference on position detection. Based on the research above, a prototype has been developed. Experimental results demonstrate that the system achieves ±0.2 mm static levitation accuracy and ±0.35 mm dynamic tracking accuracy at a movement speed of 2.7 mm/s while maintaining power consumption below 0.2 A, providing a new technical solution for low-power, miniaturized, and clinically friendly magnetic levitation capsule robots.

Authors

Institutions

Publication Details

Journal
AIP Advances
Published
2025-12-01
DOI
https://doi.org/10.1063/5.0274071
Primary Topic
Gastrointestinal Bleeding Diagnosis and Treatment
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

A low-power magnetic levitation capsule robot system based on permanent magnets-electromagnetic coils array

Shutong Deng, Shengnan Zou, Wenheng Zheng, Jian Chen
AIP Advances
Gastrointestinal Bleeding Diagnosis and Treatment
article

A low-power magnetic levitation capsule robot system based on permanent magnets-electromagnetic coils array

Shutong Deng, Shengnan Zou, Wenheng Zheng, Jian Chen
article en

Abstract

Magnetic levitation capsule robots show great promise for gastric disease diagnosis due to their non-invasive nature and low infection risk. To reduce electromagnetic coils’ power consumption and minimize the device size, this study proposes a modified magnetic levitation capsule robot system based on a commercial magnetic levitation device. Symmetrically distributed permanent magnets array provide the main levitation force, while electromagnetic coils’ array only provide horizontal restoring forces, significantly reducing power consumption. Through a bottom-mounted design, the entire apparatus is positioned beneath the hospital bed, improving clinical safety and convenience. Addressing the weakened Hall sensor signals caused by the reduced size of the capsule robot (levitating permanent magnet), we established an accurate magnetic field model, analyzed the interaction forces between the stator and capsule robot, developed a magnetic field-displacement measurement platform to precisely determine the relationship between effective signals detected by Hall sensors and capsule robot displacement, and quantified electromagnetic coils’ interference on position detection. Based on the research above, a prototype has been developed. Experimental results demonstrate that the system achieves ±0.2 mm static levitation accuracy and ±0.35 mm dynamic tracking accuracy at a movement speed of 2.7 mm/s while maintaining power consumption below 0.2 A, providing a new technical solution for low-power, miniaturized, and clinically friendly magnetic levitation capsule robots.

AIP AdvancesVol. 15(12)
Fujian University of Traditional Chinese Medicine (CN), Quanzhou Institute of Equipment Manufacturing Haixi Institute (CN), Fujian Agriculture and Forestry University (CN), Fuzhou University (CN)
Openalex Percentile: Top 47%
Gastrointestinal Bleeding Diagnosis and Treatment
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

A low-power magnetic levitation capsule robot system based on permanent magnets-electromagnetic coils array — Shutong Deng, Shengnan Zou, et al. · AIP Advances (2025) | TGRS Research Map | TGRS