SelfDenoiser: Self-supervised Seismic Signal Denoiser for Continuous and Contactless Cardiac Monitoring

Cardiovascular diseases (CVDs) remain a major global health challenge, highlighting the urgent need for advanced cardiac monitoring solutions. Continuous, contactless cardiac monitoring using seismic sensors enables comfortable, privacy-preserving assessments by capturing subtle heart vibrations. However, these systems are highly susceptible to diverse noise sources. Existing denoising methods struggle to handle the complex noise in cardiac seismic signals and poorly leverage the abundant unlabeled data. To address these challenges, we propose SelfDenoiser, a self-supervised framework for denoising and reconstructing cardiac seismic signals using unlabeled data. During training, SelfDenoiser first selects clean segments from the unlabeled pool, then injects adaptive noise into each segment to simulate shared, hard-to-remove interference commonly observed in real-world noise distributions. In addition, realistic artifacts are extracted and integrated into clean signals to model high-intensity, abrupt noise events. An encoder-decoder network designed with fixed temporal resolution is subsequently trained to recover the clean signals, guided by a loss function that captures both temporal and spectral characteristics. We evaluated SelfDenoiser on 11,392 hours of data collected in an Intensive Care Unit (ICU) using seismic sensor-based systems. The model was trained on 610 hours of clean signals selected from a 5176-hour unlabeled pool and tested on a 6216-hour labeled dataset. Results showed substantial improvements in two downstream tasks: heart rate (HR) and inter-beat interval (IBI) estimation, with notably increased data utilization and better accuracy compared to conventional denoising methods. This highlights SelfDenoiser's capability to transform low-quality, noisy signals into high-fidelity, reliable cardiac data.

Authors

Institutions

Publication Details

Journal
Proceedings of the ACM on Interactive Mobile Wearable and Ubiquitous Technologies
Published
2025-12-02
DOI
https://doi.org/10.1145/3770701
Primary Topic
Non-Invasive Vital Sign Monitoring
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

SelfDenoiser: Self-supervised Seismic Signal Denoiser for Continuous and Contactless Cardiac Monitoring

Wen‐Zhan Song, Zaipeng Xie, D. Das, Zaid Farooq Pitafi et al.
Proceedings of the ACM on Interactive Mobile Wearable and Ubiquitous Technologies
Non-Invasive Vital Sign Monitoring
article

SelfDenoiser: Self-supervised Seismic Signal Denoiser for Continuous and Contactless Cardiac Monitoring

Wen‐Zhan Song, Zaipeng Xie, D. Das, Zaid Farooq Pitafi, Zixuan Zeng, Jiayu Chen, Xiang Zhang, Jiachuan Lu, Yingjian Song, Xiao Yin, Y. ZHANG, Nishan Dong
article en

Abstract

Cardiovascular diseases (CVDs) remain a major global health challenge, highlighting the urgent need for advanced cardiac monitoring solutions. Continuous, contactless cardiac monitoring using seismic sensors enables comfortable, privacy-preserving assessments by capturing subtle heart vibrations. However, these systems are highly susceptible to diverse noise sources. Existing denoising methods struggle to handle the complex noise in cardiac seismic signals and poorly leverage the abundant unlabeled data. To address these challenges, we propose SelfDenoiser, a self-supervised framework for denoising and reconstructing cardiac seismic signals using unlabeled data. During training, SelfDenoiser first selects clean segments from the unlabeled pool, then injects adaptive noise into each segment to simulate shared, hard-to-remove interference commonly observed in real-world noise distributions. In addition, realistic artifacts are extracted and integrated into clean signals to model high-intensity, abrupt noise events. An encoder-decoder network designed with fixed temporal resolution is subsequently trained to recover the clean signals, guided by a loss function that captures both temporal and spectral characteristics. We evaluated SelfDenoiser on 11,392 hours of data collected in an Intensive Care Unit (ICU) using seismic sensor-based systems. The model was trained on 610 hours of clean signals selected from a 5176-hour unlabeled pool and tested on a 6216-hour labeled dataset. Results showed substantial improvements in two downstream tasks: heart rate (HR) and inter-beat interval (IBI) estimation, with notably increased data utilization and better accuracy compared to conventional denoising methods. This highlights SelfDenoiser's capability to transform low-quality, noisy signals into high-fidelity, reliable cardiac data.

Proceedings of the ACM on Interactive Mobile Wearable and Ubiquitous TechnologiesVol. 9(4)
University of North Carolina at Charlotte (US), Jiangsu University (CN), Hohai University (CN), University of Georgia (US), Athens Orthopedic Clinic (US), Yixing People's Hospital (CN), Ministry of Water Resources of the People's Republic of China (CN)
Openalex Percentile: Top 63%
Non-Invasive Vital Sign Monitoring
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.