Computational and Experimental Characterization of Flow in an Intubated Human Trachea

The increased incidence of respiratory diseases in the recent past has resulted in a growing number of respiratory failures and dependence on mechanical ventilation. The death rates in patients under long-term ventilator therapy are seen to be as high as 62%, with mortality often attributed to secondary bacterial infections originating in endotracheal tube (ETT) assemblies. The ETT connects the ventilator to the trachea, and the parameters selected by the clinician play important roles in determining the airflow dynamics and mucus transport. This study considers the influence of ETT cuff geometry and ventilator cycling on tracheal airflow behavior, comparing Taperguard- and Microcuff-type designs with respect to Pressure-Controlled Ventilation (PCV) and Assisted Volume-Controlled Ventilation (VCV) modes. Three-dimensional Unsteady Reynolds Averaged Navier–Stokes (URANS) simulations in an idealized intubated trachea were performed and complemented by flow visualization and flow rate measurements for model validation. The simulation results show that both the cuff geometry and ventilation mode affect flow asymmetry of air flow in the trachea and consequently the wall shear stresses and secondary flow development. Specifically, the Taperguard-style cuff under PCV conditions generated substantially elevated wall shear stress values—nearly twice those observed for the same cuff operating in VCV mode. In contrast, the Microcuff configuration paired with VCV produced lower gas flow velocities and reduced shear stress levels, reaching only about 80% of the peak values associated with the Taperguard case. These differences highlight the combined influence of cuff geometry and ventilation strategy on local airway loading. These findings highlight the coupled impact of cuff design and ventilatory mode, and provide a pathway for understanding flow physics in intubated trachea towards improved respiratory care and mechanical ventilation practices.

Authors

Institutions

Publication Details

Journal
Fluids
Published
2025-11-28
DOI
https://doi.org/10.3390/fluids10120312
Primary Topic
Nosocomial Infections in ICU
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Computational and Experimental Characterization of Flow in an Intubated Human Trachea

Ahmed Abdelaal, Aarthi Sekaran
Fluids
Nosocomial Infections in ICU
article

Computational and Experimental Characterization of Flow in an Intubated Human Trachea

Ahmed Abdelaal, Aarthi Sekaran
article en

Abstract

The increased incidence of respiratory diseases in the recent past has resulted in a growing number of respiratory failures and dependence on mechanical ventilation. The death rates in patients under long-term ventilator therapy are seen to be as high as 62%, with mortality often attributed to secondary bacterial infections originating in endotracheal tube (ETT) assemblies. The ETT connects the ventilator to the trachea, and the parameters selected by the clinician play important roles in determining the airflow dynamics and mucus transport. This study considers the influence of ETT cuff geometry and ventilator cycling on tracheal airflow behavior, comparing Taperguard- and Microcuff-type designs with respect to Pressure-Controlled Ventilation (PCV) and Assisted Volume-Controlled Ventilation (VCV) modes. Three-dimensional Unsteady Reynolds Averaged Navier–Stokes (URANS) simulations in an idealized intubated trachea were performed and complemented by flow visualization and flow rate measurements for model validation. The simulation results show that both the cuff geometry and ventilation mode affect flow asymmetry of air flow in the trachea and consequently the wall shear stresses and secondary flow development. Specifically, the Taperguard-style cuff under PCV conditions generated substantially elevated wall shear stress values—nearly twice those observed for the same cuff operating in VCV mode. In contrast, the Microcuff configuration paired with VCV produced lower gas flow velocities and reduced shear stress levels, reaching only about 80% of the peak values associated with the Taperguard case. These differences highlight the combined influence of cuff geometry and ventilation strategy on local airway loading. These findings highlight the coupled impact of cuff design and ventilatory mode, and provide a pathway for understanding flow physics in intubated trachea towards improved respiratory care and mechanical ventilation practices.

FluidsVol. 10(12)
SUNY Polytechnic Institute (US)
State University of New York, State University of New York Polytechnic Institute
Openalex Percentile: Top 54%
Nosocomial Infections in ICU
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Computational and Experimental Characterization of Flow in an Intubated Human Trachea — Ahmed Abdelaal, Aarthi Sekaran · Fluids (2025) | TGRS Research Map | TGRS