Biomechanical evaluation of different screw fixation methods for Ogawa type I coracoid process base fracture
The dual-screw fixation methods (M4 and M5) demonstrated the best stability in treating Ogawa type I coracoid process base fracture, with no significant difference between M5 and M4. For single-screw fixation, the entirely intraosseous method (M1) was more stable than the "in-out-in" methods, and the mode with partial downward exit (M2) should be avoided.
Authors
- Fang-fang Mou
- Y. H. Tan (ORCID: https://orcid.org/0000-0002-2321-7347)
- Tan Zhao (ORCID: https://orcid.org/0000-0002-5570-4799)
Institutions
- Shanghai University of Traditional Chinese Medicine (CN)
- Shuguang Hospital (CN)
Publication Details
- Journal
- JSES International
- Published
- 2025-12-02
- DOI
- https://doi.org/10.1016/j.jseint.2025.101423
- Primary Topic
- Shoulder and Clavicle Injuries
- Type
- article
- Field-Weighted Citation Impact
- 0.00