Investigation of increased cardiovascular resistance induced by endograft implantation

This study investigates the long-term cardiovascular effects of thoracic endovascular aortic repair (TEVAR), focusing on the mechanisms linking increased cardiac workload to left ventricular hypertrophy in post-procedure patients. Clinical data comparing stroke work in the pre-TEVAR and post-TEVAR conditions were analyzed alongside the cardiovascular modeling to explore hemodynamic changes. The results revealed that endograft implantation significantly disrupts vascular compliance, causing temporal misalignment between the blood flow velocity and the pressure response. Consequently, the heart must expend additional energy. A novel metric, the “propelling work ratio ,” was introduced to quantify this energy efficiency, demonstrating a marked reduction from 89.7% pre-TEVAR to 57.6% post-TEVAR. This research enhances the understanding of TEVAR-induced cardiac remodeling, providing critical insights and tools for assessing cardiovascular health post-intervention.

Authors

Institutions

Publication Details

Journal
Physics of Fluids
Published
2025-12-01
DOI
https://doi.org/10.1063/5.0293347
Citations
1
Primary Topic
Aortic Disease and Treatment Approaches
Type
article
Field-Weighted Citation Impact
1.52
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Investigation of increased cardiovascular resistance induced by endograft implantation

Yepeng Zhang, Aozui Xiao, Ji Lang, Qianqian Wang et al.
1 citations
Physics of Fluids
Aortic Disease and Treatment Approaches
1.52
article

Investigation of increased cardiovascular resistance induced by endograft implantation

Yepeng Zhang, Aozui Xiao, Ji Lang, Qianqian Wang, Min Zhou, Shijun Zhu
article en
1 citations

Abstract

This study investigates the long-term cardiovascular effects of thoracic endovascular aortic repair (TEVAR), focusing on the mechanisms linking increased cardiac workload to left ventricular hypertrophy in post-procedure patients. Clinical data comparing stroke work in the pre-TEVAR and post-TEVAR conditions were analyzed alongside the cardiovascular modeling to explore hemodynamic changes. The results revealed that endograft implantation significantly disrupts vascular compliance, causing temporal misalignment between the blood flow velocity and the pressure response. Consequently, the heart must expend additional energy. A novel metric, the “propelling work ratio ,” was introduced to quantify this energy efficiency, demonstrating a marked reduction from 89.7% pre-TEVAR to 57.6% post-TEVAR. This research enhances the understanding of TEVAR-induced cardiac remodeling, providing critical insights and tools for assessing cardiovascular health post-intervention.

Physics of FluidsVol. 37(12)
Nanjing Drum Tower Hospital (CN), Southeast University (CN)
Openalex Percentile: Top 12%
Aortic Disease and Treatment Approaches
1.52
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies