Trueness of Complete-Arch Implant Scans: Influence of Scanning Technique, Intraoral Scanner, and Implant Position (Part I: Linear and Angular Deviations)

<i>Background and Objectives</i>: This study aimed to investigate the effect of the intraoral scanner, scanning technique, and implant position on the trueness measured by linear and angular deviations. <i>Materials and Methods</i>: An edentulous maxillary model with four implants was scanned using four intraoral scanners (Trios 5, Trios 3, Primescan, Medit i700) and four scanning techniques (unmodified, composite, eugenol, dental floss). Each intraoral scanner-scanning technique combination was repeated ten times, producing 160 test datasets. Master reference files were generated with a laboratory scanner. Linear and angular deviations were calculated after superimposing each test scan with its master file. A three-way ANOVA followed by Tukey's HSD test was used to determine statistical differences. Significance was set at <i>p</i> < 0.05. <i>Results</i>: Significant effects of intraoral scanner, scanning technique, and implant position were found for both linear and angular deviations (<i>p</i> < 0.001). Trios 5 showed the highest linear deviation values, although these remained within clinically acceptable limits, while Primescan showed the lowest. Dental floss produced the highest linear and angular deviations, whereas eugenol demonstrated the lowest. Medit i700 demonstrated the lowest angular deviation. <i>Conclusions</i>: All intraoral scanners showed deviations within clinically acceptable thresholds, although Trios 5 showed the highest linear deviation. Among scanning techniques, dental floss resulted in the highest linear and angular deviations. Deviations were lower between adjacent implants and higher across 1-3, 1-4, and 2-4.

Authors

Institutions

Publication Details

Journal
Medicina
Published
2025-11-28
DOI
https://doi.org/10.3390/medicina61122127
Primary Topic
Dental Implant Techniques and Outcomes
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Trueness of Complete-Arch Implant Scans: Influence of Scanning Technique, Intraoral Scanner, and Implant Position (Part I: Linear and Angular Deviations)

Merve Çakırbay Tanış, Emre Tokar, Nihal Tokar, Bersu Bedirhandede et al.
Medicina
Dental Implant Techniques and Outcomes
article

Trueness of Complete-Arch Implant Scans: Influence of Scanning Technique, Intraoral Scanner, and Implant Position (Part I: Linear and Angular Deviations)

Merve Çakırbay Tanış, Emre Tokar, Nihal Tokar, Bersu Bedirhandede, Ayşe Demir Canbulut
article en

Abstract

<i>Background and Objectives</i>: This study aimed to investigate the effect of the intraoral scanner, scanning technique, and implant position on the trueness measured by linear and angular deviations. <i>Materials and Methods</i>: An edentulous maxillary model with four implants was scanned using four intraoral scanners (Trios 5, Trios 3, Primescan, Medit i700) and four scanning techniques (unmodified, composite, eugenol, dental floss). Each intraoral scanner-scanning technique combination was repeated ten times, producing 160 test datasets. Master reference files were generated with a laboratory scanner. Linear and angular deviations were calculated after superimposing each test scan with its master file. A three-way ANOVA followed by Tukey's HSD test was used to determine statistical differences. Significance was set at <i>p</i> < 0.05. <i>Results</i>: Significant effects of intraoral scanner, scanning technique, and implant position were found for both linear and angular deviations (<i>p</i> < 0.001). Trios 5 showed the highest linear deviation values, although these remained within clinically acceptable limits, while Primescan showed the lowest. Dental floss produced the highest linear and angular deviations, whereas eugenol demonstrated the lowest. Medit i700 demonstrated the lowest angular deviation. <i>Conclusions</i>: All intraoral scanners showed deviations within clinically acceptable thresholds, although Trios 5 showed the highest linear deviation. Among scanning techniques, dental floss resulted in the highest linear and angular deviations. Deviations were lower between adjacent implants and higher across 1-3, 1-4, and 2-4.

MedicinaVol. 61(12)
Ministry of Health (TR), Gazi University (TR)
Openalex Percentile: Top 48%
Dental Implant Techniques and Outcomes
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.