Comparison of CT-perfusion software packages and validation with true infarct core in patients with acute ischemic stroke
Our findings reveal marked variability in core volume estimates across different CTP software solutions. CMN and syngo.via B provided good accuracy, but performance declined with larger infarcts. Awareness of these discrepancies is critical for clinicians interpreting perfusion maps to optimize AIS treatment decisions and avoid misclassification of patients who might still benefit from reperfusion therapy.
Authors
- Stefan Klebingat
- Maximilian Thormann (ORCID: https://orcid.org/0000-0003-3822-8871)
- Daniel Behme (ORCID: https://orcid.org/0000-0002-5353-9515)
- Maria Faltass
- Roland Schwab (ORCID: https://orcid.org/0009-0008-3799-6194)
Institutions
- Klinikum Magdeburg (DE)
- University Hospital Magdeburg (DE)
- Charité - Universitätsmedizin Berlin (DE)
Publication Details
- Journal
- BMC Medical Imaging
- Published
- 2025-12-02
- DOI
- https://doi.org/10.1186/s12880-025-02002-7
- Primary Topic
- Acute Ischemic Stroke Management
- Type
- article
- Field-Weighted Citation Impact