Generation of severely scoliotic subject-specific musculoskeletal models

Surgical correction of severe scoliosis has been associated with high rates of complications and reoperation rates. Patient outcomes could be improved with the use of personalised scoliotic spine models. To be clinically applicable, these models must be robust to operator variability, must accurately reflect the patient anatomy, and be rapidly generated. This study developed a semi-automatic pipeline for creating subject-specific models, and the inter- and intra-operator variability and model accuracy were assessed. An existing generic spine model was modified and morphed into a subject-specific spine model using manually performed virtual anatomical landmark palpations through a semi-automatic pipeline. The inter- and intra-operator variability of the virtual palpations was assessed, and the model was compared to the ground truth of a radiographic evaluation and segmentation of computed tomography data. The interclass correlation coefficient showed excellent inter- and intra-operator repeatability (>0.9). Although significant differences were found, they were not associated with specific anatomical landmarks. The mean inter- and intra-operator variability of the virtually palpated anatomical landmarks was 2 mm, and the maximum was 10.3 mm. The vertebral centres of the patient-specific model had maximum median errors of 10.3 mm. While the mean curvature of the model reflected the radiographic measurements, there were substantial deviations from the mean. The semi-automatic pipeline successfully created a subject-specific scoliotic spine model that included automatically adjusted muscle paths. The results indicated the process was robust to inter- and intra-operator variability but would benefit from full automation, particularly to improve the definition of the intervertebral joint.

Authors

Institutions

Publication Details

Journal
PLoS ONE
Published
2025-12-01
DOI
https://doi.org/10.1371/journal.pone.0336211
Citations
1
Primary Topic
Scoliosis diagnosis and treatment
Type
article
Field-Weighted Citation Impact
2.01
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Generation of severely scoliotic subject-specific musculoskeletal models

Samuele L. Gould, Monica Cosentino, Luca Cristofolini, Giorgio Davico et al.
1 citations
PLoS ONE
Scoliosis diagnosis and treatment
2.01
article

Generation of severely scoliotic subject-specific musculoskeletal models

Samuele L. Gould, Monica Cosentino, Luca Cristofolini, Giorgio Davico, Marco Viceconti
article en
1 citations

Abstract

Surgical correction of severe scoliosis has been associated with high rates of complications and reoperation rates. Patient outcomes could be improved with the use of personalised scoliotic spine models. To be clinically applicable, these models must be robust to operator variability, must accurately reflect the patient anatomy, and be rapidly generated. This study developed a semi-automatic pipeline for creating subject-specific models, and the inter- and intra-operator variability and model accuracy were assessed. An existing generic spine model was modified and morphed into a subject-specific spine model using manually performed virtual anatomical landmark palpations through a semi-automatic pipeline. The inter- and intra-operator variability of the virtual palpations was assessed, and the model was compared to the ground truth of a radiographic evaluation and segmentation of computed tomography data. The interclass correlation coefficient showed excellent inter- and intra-operator repeatability (>0.9). Although significant differences were found, they were not associated with specific anatomical landmarks. The mean inter- and intra-operator variability of the virtually palpated anatomical landmarks was 2 mm, and the maximum was 10.3 mm. The vertebral centres of the patient-specific model had maximum median errors of 10.3 mm. While the mean curvature of the model reflected the radiographic measurements, there were substantial deviations from the mean. The semi-automatic pipeline successfully created a subject-specific scoliotic spine model that included automatically adjusted muscle paths. The results indicated the process was robust to inter- and intra-operator variability but would benefit from full automation, particularly to improve the definition of the intervertebral joint.

PLoS ONEVol. 20(12)
Istituto Ortopedico Rizzoli (IT), University of Bologna (IT)
Openalex Percentile: Top 10%
Scoliosis diagnosis and treatment
2.01
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.