Collagen IV-targeted phase-change nanoparticles illuminate early liver fibrosis staging <i>via</i> ultrasound molecular imaging

Early non-invasive diagnosis of liver fibrosis remains a significant clinical challenge. This study aimed to develop type IV collagen-targeted phase-change nanoparticles (AC-IV-PFP@NPs) for ultrasound molecular imaging (UMI), allowing accurate staging of early-stage liver fibrosis. AC-IV-PFP@NPs were prepared by conjugating anti-collagen IV antibody (AC-IV) to perfluoropentane-encapsulated liposomes <i>via</i> carbodiimide coupling. Physicochemical properties were characterized using transmission electron microscopy, dynamic light scattering, and confocal microscopy. In CCl<sub>4</sub>-induced fibrotic rats representing METAVIR stages S0-S4, the targeted nanoparticles were administered intravenously. The nanoparticles displayed spherical morphology with a mean diameter of 307.92 ± 4.16 nm, high AC-IV conjugation efficiency (78.94 ± 2.83%), and a favorable biosafety profile (cell viability >87% at 6 mg mL<sup>-1</sup>). Targeting specificity was validated both <i>in vitro</i> and <i>in vivo</i>, with fluorescence imaging showing a 3.8-fold increase in binding to fibrotic collagen IV relative to non-targeted controls (<i>P</i> < 0.001). CEUS signal intensity peaked at 30 min post-injection and showed a strong positive correlation with the fibrosis stage (<i>r</i> = 0.725, <i>P</i> < 0.001). ROC analysis demonstrated high diagnostic accuracy for early fibrosis: an area under the curve (AUC) of 0.949 for distinguishing S0 from S1-S4 (sensitivity 85.5%, specificity 91.7%) and an AUC of 0.923 for separating S0-S1 from S2-S4 (sensitivity 90.7%, specificity 79.2%). To date, AC-IV-PFP@NPs represent the first type IV collagen-targeted UMI platform for liver fibrosis staging in rats, offering non-invasive, real-time assessment with high sensitivity for early-stage disease (S1-S2). This approach addresses the limitations of biopsy and conventional imaging and offers a promising and transformative approach for clinical fibrosis management.

Authors

Institutions

Publication Details

Journal
Biomaterials Science
Published
2025-12-01
DOI
https://doi.org/10.1039/d5bm01181g
Primary Topic
Ultrasound and Hyperthermia Applications
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Collagen IV-targeted phase-change nanoparticles illuminate early liver fibrosis staging via ultrasound molecular imaging

Yaqin Hu, Long Cheng, Haitao Ran, Shigen Zhong et al.
Biomaterials Science
Ultrasound and Hyperthermia Applications
article

Collagen IV-targeted phase-change nanoparticles illuminate early liver fibrosis staging via ultrasound molecular imaging

Yaqin Hu, Long Cheng, Haitao Ran, Shigen Zhong, Yan Long, Min Zheng, Wei Zhang, Fang Li, Mingyuan Dai
article en

Abstract

Early non-invasive diagnosis of liver fibrosis remains a significant clinical challenge. This study aimed to develop type IV collagen-targeted phase-change nanoparticles (AC-IV-PFP@NPs) for ultrasound molecular imaging (UMI), allowing accurate staging of early-stage liver fibrosis. AC-IV-PFP@NPs were prepared by conjugating anti-collagen IV antibody (AC-IV) to perfluoropentane-encapsulated liposomes <i>via</i> carbodiimide coupling. Physicochemical properties were characterized using transmission electron microscopy, dynamic light scattering, and confocal microscopy. In CCl<sub>4</sub>-induced fibrotic rats representing METAVIR stages S0-S4, the targeted nanoparticles were administered intravenously. The nanoparticles displayed spherical morphology with a mean diameter of 307.92 ± 4.16 nm, high AC-IV conjugation efficiency (78.94 ± 2.83%), and a favorable biosafety profile (cell viability >87% at 6 mg mL<sup>-1</sup>). Targeting specificity was validated both <i>in vitro</i> and <i>in vivo</i>, with fluorescence imaging showing a 3.8-fold increase in binding to fibrotic collagen IV relative to non-targeted controls (<i>P</i> < 0.001). CEUS signal intensity peaked at 30 min post-injection and showed a strong positive correlation with the fibrosis stage (<i>r</i> = 0.725, <i>P</i> < 0.001). ROC analysis demonstrated high diagnostic accuracy for early fibrosis: an area under the curve (AUC) of 0.949 for distinguishing S0 from S1-S4 (sensitivity 85.5%, specificity 91.7%) and an AUC of 0.923 for separating S0-S1 from S2-S4 (sensitivity 90.7%, specificity 79.2%). To date, AC-IV-PFP@NPs represent the first type IV collagen-targeted UMI platform for liver fibrosis staging in rats, offering non-invasive, real-time assessment with high sensitivity for early-stage disease (S1-S2). This approach addresses the limitations of biopsy and conventional imaging and offers a promising and transformative approach for clinical fibrosis management.

Biomaterials ScienceVol. 14(2)
Chongqing University (CN), Dalian Medical University (CN), Second Affiliated Hospital of Chongqing Medical University (CN), First People's Hospital of Chongqing (CN), Chongqing Medical University (CN)
National Natural Science Foundation of China, Centre Scientifique et Technique du Bâtiment
Openalex Percentile: Top 63%
Ultrasound and Hyperthermia Applications
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.