Research on calibration method of fault flashover test instrument for power cable using low voltage pulse method

The fault flashover test instrument for power cable is an indispensable equipment in cable fault detection work. Low voltage pulse method is one of the common methods for cable fault testing. Accurate and reliable measurement values are of great significance for fault flashover test instrument for power cable using low voltage pulse method. This paper presents a calibration method that is easy to operate, mainly uses common equipment as measurement standards, and has a low calibration cost. The article elaborates in detail on the key steps in the calibration process, including the selection of standard equipment, operation methods, data processing, etc., and verifies the effectiveness of the proposed calibration method through experiments.

Authors

Institutions

Publication Details

Journal
IET conference proceedings.
Published
2025-12-01
DOI
https://doi.org/10.1049/icp.2025.3328
Primary Topic
Electrical Fault Detection and Protection
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Research on calibration method of fault flashover test instrument for power cable using low voltage pulse method

Wei Cui, Qian Chen, Xiaojie Sun, Shang Wang et al.
IET conference proceedings.
Electrical Fault Detection and Protection
article

Research on calibration method of fault flashover test instrument for power cable using low voltage pulse method

Wei Cui, Qian Chen, Xiaojie Sun, Shang Wang, Qing‐Yu He, Mu Wang
article en

Abstract

The fault flashover test instrument for power cable is an indispensable equipment in cable fault detection work. Low voltage pulse method is one of the common methods for cable fault testing. Accurate and reliable measurement values are of great significance for fault flashover test instrument for power cable using low voltage pulse method. This paper presents a calibration method that is easy to operate, mainly uses common equipment as measurement standards, and has a low calibration cost. The article elaborates in detail on the key steps in the calibration process, including the selection of standard equipment, operation methods, data processing, etc., and verifies the effectiveness of the proposed calibration method through experiments.

IET conference proceedings.Vol. 2025(30)
Shandong Institute of Metrology (CN)
Openalex Percentile: Top 63%
Electrical Fault Detection and Protection
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.