Real-time wavelength-calibrated laser heterodyne radiometer based on an all-fiber unbalanced Mach-Zehnder interferometer

Laser heterodyne spectroscopy is facilitating groundbreaking advances across multiple fields, including planetary atmospheric exploration, terrestrial greenhouse gas monitoring, wind field measurements, isotopic ratio analysis, and industrial gas emission monitoring. Nevertheless, Laser heterodyne radiometers (LHRs) lack effective wavelength calibration methods, which hinders their application in scenarios requiring miniaturization, high stability, and high precision. In this paper, what we believe to be a novel all-fiber LHR capable of real-time wavelength calibration is presented. The wavelength calibration scheme for this LHR was implemented using an all-fiber unbalanced Mach-Zehnder interferometer (MZI) combined with a corresponding wavelength calibration algorithm. Key performance-limiting factors of unbalanced MZI were experimentally analyzed. The criteria for determining the optimal optical path difference of the unbalanced MZI were established for the first time specifically for LHR applications. With a 22 cm unbalanced arm design, the system achieved a calibration resolution of 0.01623 cm<sup>-1</sup> and demonstrated a calibration uncertainty of 2 × 10<sup>-5 </sup>cm<sup>-1</sup> at an averaging time of 1s. Its performance was validated through absorption spectra measurements conducted in a gas cell. Field measurements of atmospheric CO<sub>2</sub> absorption spectra were performed with the developed real-time wavelength-calibrated LHR. The unbalanced MZI wavelength calibration scheme not only provides a high-precision, environmentally robust frequency scale for laser heterodyne absorption spectroscopy but also exhibits great potential to serve as a reliable calibration solution for other high-resolution spectroscopic techniques.

Authors

Institutions

Publication Details

Journal
Optics Express
Published
2025-12-01
DOI
https://doi.org/10.1364/oe.581717
Primary Topic
Spectroscopy and Laser Applications
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Real-time wavelength-calibrated laser heterodyne radiometer based on an all-fiber unbalanced Mach-Zehnder interferometer

Jingjing Wang, Guowei Wang, Jun Li, Kun Liu et al.
Optics Express
Spectroscopy and Laser Applications
article

Real-time wavelength-calibrated laser heterodyne radiometer based on an all-fiber unbalanced Mach-Zehnder interferometer

Jingjing Wang, Guowei Wang, Jun Li, Kun Liu, Xiaoming Gao, Tu Tan
article en

Abstract

Laser heterodyne spectroscopy is facilitating groundbreaking advances across multiple fields, including planetary atmospheric exploration, terrestrial greenhouse gas monitoring, wind field measurements, isotopic ratio analysis, and industrial gas emission monitoring. Nevertheless, Laser heterodyne radiometers (LHRs) lack effective wavelength calibration methods, which hinders their application in scenarios requiring miniaturization, high stability, and high precision. In this paper, what we believe to be a novel all-fiber LHR capable of real-time wavelength calibration is presented. The wavelength calibration scheme for this LHR was implemented using an all-fiber unbalanced Mach-Zehnder interferometer (MZI) combined with a corresponding wavelength calibration algorithm. Key performance-limiting factors of unbalanced MZI were experimentally analyzed. The criteria for determining the optimal optical path difference of the unbalanced MZI were established for the first time specifically for LHR applications. With a 22 cm unbalanced arm design, the system achieved a calibration resolution of 0.01623 cm<sup>-1</sup> and demonstrated a calibration uncertainty of 2 × 10<sup>-5 </sup>cm<sup>-1</sup> at an averaging time of 1s. Its performance was validated through absorption spectra measurements conducted in a gas cell. Field measurements of atmospheric CO<sub>2</sub> absorption spectra were performed with the developed real-time wavelength-calibrated LHR. The unbalanced MZI wavelength calibration scheme not only provides a high-precision, environmentally robust frequency scale for laser heterodyne absorption spectroscopy but also exhibits great potential to serve as a reliable calibration solution for other high-resolution spectroscopic techniques.

Optics ExpressVol. 34(2)
University of Science and Technology of China (CN), University of Shanghai for Science and Technology (CN)
Openalex Percentile: Top 66%
Spectroscopy and Laser Applications
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.