A portable dry-electrode ECG device for rapid and accurate neonatal heart rate monitoring during resuscitation

Each year, around 10% of infants globally will require resuscitation at birth. Pediatricians can use stethoscope, electrocardiogram (ECG) or pulse oximetry to determine heart rate (HR) which is used to guide resuscitation steps. HR must be acquired accurately and quickly. However, current HR detection modalities are either inaccurate or too slow. This work offers a novel infant heart rate detector (iHRD) using single-lead dry electrode ECG that can display HR accurately within the first 10 seconds of initial contact. A research ethics board approved validation study is conducted on 50 healthy newborns comparing iHRD's HR with clinical HR monitors at a community hospital. 3-minute newborn single-lead ECGs and HR are recorded, and HR is annotated every 2 seconds. Statistical HR analysis is performed to ensure iHRD's feasibility and reliability. With 2741 HR datapoints, excluding outliers, the iHRD detected HR with 94.5% accuracy with time from contact to HR display under 10 seconds. Overall, the iHRD using dry electrode single-lead ECG showed good results in providing reliable HR quickly for neonatal resuscitation efforts.

Authors

Institutions

Publication Details

Journal
Scientific Reports
Published
2025-12-01
DOI
https://doi.org/10.1038/s41598-025-27045-2
Primary Topic
Non-Invasive Vital Sign Monitoring
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

A portable dry-electrode ECG device for rapid and accurate neonatal heart rate monitoring during resuscitation

Niraj Mistry, Abdelrahman Abdou, Sridhar Krishnan
Scientific Reports
Non-Invasive Vital Sign Monitoring
article

A portable dry-electrode ECG device for rapid and accurate neonatal heart rate monitoring during resuscitation

Niraj Mistry, Abdelrahman Abdou, Sridhar Krishnan
article en

Abstract

Each year, around 10% of infants globally will require resuscitation at birth. Pediatricians can use stethoscope, electrocardiogram (ECG) or pulse oximetry to determine heart rate (HR) which is used to guide resuscitation steps. HR must be acquired accurately and quickly. However, current HR detection modalities are either inaccurate or too slow. This work offers a novel infant heart rate detector (iHRD) using single-lead dry electrode ECG that can display HR accurately within the first 10 seconds of initial contact. A research ethics board approved validation study is conducted on 50 healthy newborns comparing iHRD's HR with clinical HR monitors at a community hospital. 3-minute newborn single-lead ECGs and HR are recorded, and HR is annotated every 2 seconds. Statistical HR analysis is performed to ensure iHRD's feasibility and reliability. With 2741 HR datapoints, excluding outliers, the iHRD detected HR with 94.5% accuracy with time from contact to HR display under 10 seconds. Overall, the iHRD using dry electrode single-lead ECG showed good results in providing reliable HR quickly for neonatal resuscitation efforts.

Scientific ReportsVol. 15(1)
University of Toronto (CA), Scarborough Health Network (CA), Hospital for Sick Children (CA)
Natural Sciences and Engineering Research Council of Canada
Openalex Percentile: Top 63%
Non-Invasive Vital Sign Monitoring
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

A portable dry-electrode ECG device for rapid and accurate neonatal heart rate monitoring during resuscitation — Niraj Mistry, Abdelrahman Abdou, et al. · Scientific Reports (2025) | TGRS Research Map | TGRS