Quantitative assessment of the standard method for measuring steam composition in surface sterilisation

Steam composition, defined as the fraction of non-condensable gases (NCGs) in the steam, is an essential parameter to ensure the efficacy and reliability of the steam sterilisation process. Standard EN 285:2015 + A1:2021 defines an operative method for measuring NCG fraction (NCG%) in the steriliser steam pipes, but lacks specifications about the process profile, timing and volume of condensate, and environmental conditions. This study aimed to quantify the effects of this lack of specifications on NCG% measured values to enable a more effective and informative testing procedure. Sterilisation processes, with different profiles and load amounts, were run in a medium-sized steam steriliser. NCGs and steam condensate volumes were measured every 30 s using the standard method, and NCG% values were calculated at different time points and condensate volumes. NCG% variations associated with environmental temperature and pressure were theoretically estimated. NCG% values and test outcomes showed dependence on the process profile, load, condensate collection timing and volume. Environmental conditions had a non-negligible impact on measurements. Overall, NCG measurement variability impacted standard method reliability to qualify the steriliser and to estimate steam composition in the steriliser chamber. Real-time quantitative monitoring of steam composition during every production process is advocated to improve steam sterilisation efficacy and quality.

Authors

Institutions

Publication Details

Journal
Scientific Reports
Published
2025-12-01
DOI
https://doi.org/10.1038/s41598-025-26981-3
Primary Topic
Medical Device Sterilization and Disinfection
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Quantitative assessment of the standard method for measuring steam composition in surface sterilisation

Michela Masè, Francesco Tessarolo
Scientific Reports
Medical Device Sterilization and Disinfection
article

Quantitative assessment of the standard method for measuring steam composition in surface sterilisation

Michela Masè, Francesco Tessarolo
article en

Abstract

Steam composition, defined as the fraction of non-condensable gases (NCGs) in the steam, is an essential parameter to ensure the efficacy and reliability of the steam sterilisation process. Standard EN 285:2015 + A1:2021 defines an operative method for measuring NCG fraction (NCG%) in the steriliser steam pipes, but lacks specifications about the process profile, timing and volume of condensate, and environmental conditions. This study aimed to quantify the effects of this lack of specifications on NCG% measured values to enable a more effective and informative testing procedure. Sterilisation processes, with different profiles and load amounts, were run in a medium-sized steam steriliser. NCGs and steam condensate volumes were measured every 30 s using the standard method, and NCG% values were calculated at different time points and condensate volumes. NCG% variations associated with environmental temperature and pressure were theoretically estimated. NCG% values and test outcomes showed dependence on the process profile, load, condensate collection timing and volume. Environmental conditions had a non-negligible impact on measurements. Overall, NCG measurement variability impacted standard method reliability to qualify the steriliser and to estimate steam composition in the steriliser chamber. Real-time quantitative monitoring of steam composition during every production process is advocated to improve steam sterilisation efficacy and quality.

Scientific ReportsVol. 15(1)
University of Trento (IT), Fondazione Bruno Kessler (IT)
European Commission, European Social Fund
Openalex Percentile: Top 64%
Medical Device Sterilization and Disinfection
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Quantitative assessment of the standard method for measuring steam composition in surface sterilisation — Michela Masè, Francesco Tessarolo · Scientific Reports (2025) | TGRS Research Map | TGRS