Transcatheter pulmonary valve implantation following prosthesis modification: lessons from a small bioIntegral prosthetic valve

The clinical case describes a 13-year-old boy with a history of transposition of the great arteries, ventricular septal defect, and pulmonary stenosis who underwent surgical correction at age 1 with the REV procedure and the Lecompte maneuver. At age 2, severe subaortic obstruction required reoperation for subaortic tunnel reconstruction, myectomy, and reimplantation. Due to severe right ventricular outflow tract dysfunction, a 19 mm No-React Injectable BioPulmonic prosthesis was implanted. At 12 years, the patient presented with reduced exercise tolerance. Echocardiography and cardiac catheterisation demonstrated severe stenosis and regurgitation of the pulmonary bioprosthesis, right ventricular dilatation and hypertrophy, and an increased right ventricular-pulmonary artery gradient with normal pulmonary artery pressures. The manuscript presents an in vitro test demonstrating that the No-React Injectable BioPulmonic prosthesis frame can be modified using high-pressure balloons to increase its true inner diameter. The patient subsequently underwent transcatheter valve-in-valve implantation of a 23 mm Sapien 3 following pre-dilation and frame modification of the 19 mm No-React Injectable BioPulmonic prosthesis with a 22 × 20 mm Atlas Gold balloon, achieving an favourable haemodynamic outcome. Post-implant pulmonary arteriography excluded any intra-perivalvular regurgitation. Post-procedure haemodynamic assessment showed a residual peak-to-peak gradient of 10 mmHg, with systolic right ventricular pressures below half of systemic pressure. At the 6-month follow-up after the procedure, the post-procedural peak echocardiographic gradient across the pulmonary prosthesis was measured at 28 mmHg, with no evidence of regurgitation. Short-term results have been optimal, which encourages the use of this strategy for the treatment of similar cases.

Authors

Institutions

Publication Details

Journal
Cardiology in the Young
Published
2025-12-01
DOI
https://doi.org/10.1017/s1047951125110287
Primary Topic
Congenital Heart Disease Studies
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Transcatheter pulmonary valve implantation following prosthesis modification: lessons from a small bioIntegral prosthetic valve

Andrea Laurito, G Giusti, Marco Papa
Cardiology in the Young
Congenital Heart Disease Studies
article

Transcatheter pulmonary valve implantation following prosthesis modification: lessons from a small bioIntegral prosthetic valve

Andrea Laurito, G Giusti, Marco Papa
article en

Abstract

The clinical case describes a 13-year-old boy with a history of transposition of the great arteries, ventricular septal defect, and pulmonary stenosis who underwent surgical correction at age 1 with the REV procedure and the Lecompte maneuver. At age 2, severe subaortic obstruction required reoperation for subaortic tunnel reconstruction, myectomy, and reimplantation. Due to severe right ventricular outflow tract dysfunction, a 19 mm No-React Injectable BioPulmonic prosthesis was implanted. At 12 years, the patient presented with reduced exercise tolerance. Echocardiography and cardiac catheterisation demonstrated severe stenosis and regurgitation of the pulmonary bioprosthesis, right ventricular dilatation and hypertrophy, and an increased right ventricular-pulmonary artery gradient with normal pulmonary artery pressures. The manuscript presents an in vitro test demonstrating that the No-React Injectable BioPulmonic prosthesis frame can be modified using high-pressure balloons to increase its true inner diameter. The patient subsequently underwent transcatheter valve-in-valve implantation of a 23 mm Sapien 3 following pre-dilation and frame modification of the 19 mm No-React Injectable BioPulmonic prosthesis with a 22 × 20 mm Atlas Gold balloon, achieving an favourable haemodynamic outcome. Post-implant pulmonary arteriography excluded any intra-perivalvular regurgitation. Post-procedure haemodynamic assessment showed a residual peak-to-peak gradient of 10 mmHg, with systolic right ventricular pressures below half of systemic pressure. At the 6-month follow-up after the procedure, the post-procedural peak echocardiographic gradient across the pulmonary prosthesis was measured at 28 mmHg, with no evidence of regurgitation. Short-term results have been optimal, which encourages the use of this strategy for the treatment of similar cases.

Cardiology in the YoungVol. 36(1)
Ospedale Maggiore (IT), Ospedale Maggiore Carlo Alberto Pizzardi (IT), University of Milano-Bicocca (IT)
Openalex Percentile: Top 51%
Congenital Heart Disease Studies
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.