EVALUATION OF FABRICATION ACCURACY AND PASSIVITY OF SELECTIVE LASER MELTING VERSUS CONVENTIONAL METAL BAR ON MANDIBULAR IMPLANT OVERDENTURE AN IN-VITRO STUDY

Purpose: The purpose of this study was to evaluate and compare the fabrication accuracy and passivity of conventionally constructed bars and selective laser melting (SLM) bars by Digital Subtractive Technique using Medit-Compare and one screw test.Material and Methods: The study involved the fabrication of cobalt chromium bars for an in-vitro edentulous mandibular model with two implants. Two groups of bars were made using different techniques: Group A bars were produced via the lost wax technique by milling a castable resin, and Group B bars were fabricated using selective laser melting (SLM). The mandibular model construction involved scanning a stone model, creating digital template and 3d printed. The fabrication accuracy of the bars was evaluated using scanning and superimposition using medit compare software while one-screw test was used to evaluate passivity.Results: The findings showed a non-significant difference in the accuracy of the bar attachment fabricated using the conventional method compared to those produced with SLM. Regarding passive fit, the SLM technique demonstrated a higher percentage of prostheses achieving passivity compared to the conventional method. However, this difference was not statistically significant. Conclusion: Within the limitations of this study, SLM-fabricated bar attachments exhibited an overall accuracy similar to that of conventional casted Bars. Regarding passive fit, the SLM technique demonstrated a higher percentage of prostheses achieving passivity compared to the conventional method. However, this difference was not statistically significant.

Authors

Institutions

Publication Details

Journal
Al-Azhar Journal of Dental Science
Published
2025-10-01
DOI
https://doi.org/10.21608/ajdsm.2025.348974.1596
Primary Topic
Laser Applications in Dentistry and Medicine
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

EVALUATION OF FABRICATION ACCURACY AND PASSIVITY OF SELECTIVE LASER MELTING VERSUS CONVENTIONAL METAL BAR ON MANDIBULAR IMPLANT OVERDENTURE AN IN-VITRO STUDY

Mai Helmy, nouran Gamal Lasheen, Enas Taha
Al-Azhar Journal of Dental Science
Laser Applications in Dentistry and Medicine
article

EVALUATION OF FABRICATION ACCURACY AND PASSIVITY OF SELECTIVE LASER MELTING VERSUS CONVENTIONAL METAL BAR ON MANDIBULAR IMPLANT OVERDENTURE AN IN-VITRO STUDY

Mai Helmy, nouran Gamal Lasheen, Enas Taha
article en

Abstract

Purpose: The purpose of this study was to evaluate and compare the fabrication accuracy and passivity of conventionally constructed bars and selective laser melting (SLM) bars by Digital Subtractive Technique using Medit-Compare and one screw test.Material and Methods: The study involved the fabrication of cobalt chromium bars for an in-vitro edentulous mandibular model with two implants. Two groups of bars were made using different techniques: Group A bars were produced via the lost wax technique by milling a castable resin, and Group B bars were fabricated using selective laser melting (SLM). The mandibular model construction involved scanning a stone model, creating digital template and 3d printed. The fabrication accuracy of the bars was evaluated using scanning and superimposition using medit compare software while one-screw test was used to evaluate passivity.Results: The findings showed a non-significant difference in the accuracy of the bar attachment fabricated using the conventional method compared to those produced with SLM. Regarding passive fit, the SLM technique demonstrated a higher percentage of prostheses achieving passivity compared to the conventional method. However, this difference was not statistically significant. Conclusion: Within the limitations of this study, SLM-fabricated bar attachments exhibited an overall accuracy similar to that of conventional casted Bars. Regarding passive fit, the SLM technique demonstrated a higher percentage of prostheses achieving passivity compared to the conventional method. However, this difference was not statistically significant.

Al-Azhar Journal of Dental ScienceVol. 28(4)
Cairo University (EG)
Openalex Percentile: Top 48%
Laser Applications in Dentistry and Medicine
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.