The impact of implant diameter on strain around implant retaining mandibular overdentures with bar attachments (An in vitro study)

Objectives: This vitro study's objective was to assess the impact of implant diameter on strain around implants retaining mandibular overdentures with bar attachments Purpose :The aim of this in vitro study was to evulate , by means of strain gauge analysis , the effect of different implant diameters on strain around two-implants retaining a mandibular over denture with bar attachments.Material and Methods: Three epoxy models with silicon mucosal simulation was fabricated and two laboratory implants were inserted in canine areas.according to implant diameter ,the experimental casts were randomly divided into 3 groups, groupI(4.3mm), groupII(3.8mm),groupIII(3mm)and all implants had a length of 10mm.three denture were fabricated and connected to implants with bar attachments. Four linear strain gauges were bonded to the epoxy resin at mesial, distal, buccal ,lingual surfaces of each implant. 100N static load was applied unilaterally over frist molar positions. Starins were measured at mesial,distal,buccal,lingual peri-implant sites. Loading side and non loading side Results: the results showed that for loading and non loading side ,for majority of surfaces and for molar positions small diameter implants recorded the highest strain, followed by medium diameter implants and the smallest strain was recorded with large diameter implants Conclusion: it is recommended to use the largest implant diameter as possible to minimize peri-implant strain when bar attachments are used to retained mandibular overdentures to implants Randomized controlled clinical trials are needed to evulate the effect of different implant diameters on peri-implant crestal alveolar bone loss Key words : implant ,overdenture, bar ,strain

Authors

Institutions

Publication Details

Journal
Al-Azhar Journal of Dental Science
Published
2025-10-01
DOI
https://doi.org/10.21608/ajdsm.2023.236940.1469
Primary Topic
Dental Implant Techniques and Outcomes
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

The impact of implant diameter on strain around implant retaining mandibular overdentures with bar attachments (An in vitro study)

Maurice Salama, Adel M. Abdel-Hakim, Nehad Harby
Al-Azhar Journal of Dental Science
Dental Implant Techniques and Outcomes
article

The impact of implant diameter on strain around implant retaining mandibular overdentures with bar attachments (An in vitro study)

Maurice Salama, Adel M. Abdel-Hakim, Nehad Harby
article en

Abstract

Objectives: This vitro study's objective was to assess the impact of implant diameter on strain around implants retaining mandibular overdentures with bar attachments Purpose :The aim of this in vitro study was to evulate , by means of strain gauge analysis , the effect of different implant diameters on strain around two-implants retaining a mandibular over denture with bar attachments.Material and Methods: Three epoxy models with silicon mucosal simulation was fabricated and two laboratory implants were inserted in canine areas.according to implant diameter ,the experimental casts were randomly divided into 3 groups, groupI(4.3mm), groupII(3.8mm),groupIII(3mm)and all implants had a length of 10mm.three denture were fabricated and connected to implants with bar attachments. Four linear strain gauges were bonded to the epoxy resin at mesial, distal, buccal ,lingual surfaces of each implant. 100N static load was applied unilaterally over frist molar positions. Starins were measured at mesial,distal,buccal,lingual peri-implant sites. Loading side and non loading side Results: the results showed that for loading and non loading side ,for majority of surfaces and for molar positions small diameter implants recorded the highest strain, followed by medium diameter implants and the smallest strain was recorded with large diameter implants Conclusion: it is recommended to use the largest implant diameter as possible to minimize peri-implant strain when bar attachments are used to retained mandibular overdentures to implants Randomized controlled clinical trials are needed to evulate the effect of different implant diameters on peri-implant crestal alveolar bone loss Key words : implant ,overdenture, bar ,strain

Al-Azhar Journal of Dental ScienceVol. 28(4)
Al-Azhar University (ID)
Openalex Percentile: Top 48%
Dental Implant Techniques and Outcomes
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

The impact of implant diameter on strain around implant retaining mandibular overdentures with bar attachments (An in vitro study) — Maurice Salama, Adel M. Abdel-Hakim, et al. · Al-Azhar Journal of Dental Science (2025) | TGRS Research Map | TGRS