An unusual avulsion of the prosthetic aortic valve with an aortic root pseudoaneurysm: a case report

Complete avulsion accompanied by aortic root pseudoaneurysm is a rare complication of infective endocarditis (IE). Transesophageal echocardiography (TEE) plays an important role in perioperative evaluation. A 38-year-old male patient, who underwent a Bentall procedure for an aortic aneurysm 8 years ago, was admitted with avulsion of a prosthetic aortic valve caused by IE. This led to significant structural damage and the development of an aortic root pseudoaneurysm. TEE provided real-time, multidimensional insights into IE-induced changes in adjacent structures and allowed detailed assessment of the composite graft’s integrity. A combined Bentall-Cabrol procedure was successfully performed, guided precisely by TEE findings. This included management of the floating prosthetic aortic valve and reconstruction of the aortic annulus. This case highlights the valuable role of TEE in diagnosing and guiding complex surgical interventions for IE, particularly when involving prosthetic valve complications.

Authors

Institutions

Publication Details

Journal
Journal of Cardiothoracic Surgery
Published
2025-12-01
DOI
https://doi.org/10.1186/s13019-025-03758-3
Primary Topic
Infective Endocarditis Diagnosis and Management
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

An unusual avulsion of the prosthetic aortic valve with an aortic root pseudoaneurysm: a case report

Mingjing Chen, Haibo Song, Jingdan Deng, Zhenghua Xiao
Journal of Cardiothoracic Surgery
Infective Endocarditis Diagnosis and Management
article

An unusual avulsion of the prosthetic aortic valve with an aortic root pseudoaneurysm: a case report

Mingjing Chen, Haibo Song, Jingdan Deng, Zhenghua Xiao
article en

Abstract

Complete avulsion accompanied by aortic root pseudoaneurysm is a rare complication of infective endocarditis (IE). Transesophageal echocardiography (TEE) plays an important role in perioperative evaluation. A 38-year-old male patient, who underwent a Bentall procedure for an aortic aneurysm 8 years ago, was admitted with avulsion of a prosthetic aortic valve caused by IE. This led to significant structural damage and the development of an aortic root pseudoaneurysm. TEE provided real-time, multidimensional insights into IE-induced changes in adjacent structures and allowed detailed assessment of the composite graft’s integrity. A combined Bentall-Cabrol procedure was successfully performed, guided precisely by TEE findings. This included management of the floating prosthetic aortic valve and reconstruction of the aortic annulus. This case highlights the valuable role of TEE in diagnosing and guiding complex surgical interventions for IE, particularly when involving prosthetic valve complications.

Journal of Cardiothoracic SurgeryVol. 21(1)
Johns Hopkins University (US), Sichuan University (CN), Johns Hopkins Medicine (US), Meizhou City People's Hospital (CN), West China Hospital of Sichuan University (CN)
Openalex Percentile: Top 51%
Infective Endocarditis Diagnosis and Management
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

An unusual avulsion of the prosthetic aortic valve with an aortic root pseudoaneurysm: a case report — Mingjing Chen, Haibo Song, et al. · Journal of Cardiothoracic Surgery (2025) | TGRS Research Map | TGRS