Accessible Protein Quantification with a Low-Cost Spectrophotometer Using Bradford Reagent

Ensuring accessible and cost-effective laboratory equipment is essential for advancing scientific research in resource-limited settings. This study introduces a novel; low-cost spectrophotometer built with an Arduino microcontroller and a BH1750 light sensor to measure protein concentration using the Bradford method. The device features a 595 nm LED as the light source, encased in a 3D-printed PLA filament housing. Casein served as the standard protein for calibration and testing. The system demonstrated a linear detection range of 100 to 700 ppm, with a regression equation of y = 0.0007x + 0.1418 and a high correlation coefficient (R2 = 0.9921) compared to commercial spectrophotometers. The limit of detection and quantification were 58.43 and 194.77 ppm, respectively. Precision was confirmed with a HORRAT value of 0.161 using a 500 ppm sample, and accuracy was 103.34% for a 100 ppm sample. The device showed good selectivity against 200 ppm glucose interference. This open-source solution significantly reduces the cost of spectrophotometric analysis while improving accessibility in educational and remote laboratories. The practical implication of this study is it has strong potential for use in educational settings and field-based protein quantification due to its low cost, portability, and adequate performance.

Authors

Institutions

Publication Details

Journal
Indonesian Journal of Chemistry
Published
2025-12-01
DOI
https://doi.org/10.22146/ijc.99362
Primary Topic
Biosensors and Analytical Detection
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Accessible Protein Quantification with a Low-Cost Spectrophotometer Using Bradford Reagent

Mekar Dwi Anggraeni, Hartiwi Diastuti, Dadan Hermawan, Amin Fatoni et al.
Indonesian Journal of Chemistry
Biosensors and Analytical Detection
article

Accessible Protein Quantification with a Low-Cost Spectrophotometer Using Bradford Reagent

Mekar Dwi Anggraeni, Hartiwi Diastuti, Dadan Hermawan, Amin Fatoni, Novia Rahmandani Shoobiroh
article en

Abstract

Ensuring accessible and cost-effective laboratory equipment is essential for advancing scientific research in resource-limited settings. This study introduces a novel; low-cost spectrophotometer built with an Arduino microcontroller and a BH1750 light sensor to measure protein concentration using the Bradford method. The device features a 595 nm LED as the light source, encased in a 3D-printed PLA filament housing. Casein served as the standard protein for calibration and testing. The system demonstrated a linear detection range of 100 to 700 ppm, with a regression equation of y = 0.0007x + 0.1418 and a high correlation coefficient (R2 = 0.9921) compared to commercial spectrophotometers. The limit of detection and quantification were 58.43 and 194.77 ppm, respectively. Precision was confirmed with a HORRAT value of 0.161 using a 500 ppm sample, and accuracy was 103.34% for a 100 ppm sample. The device showed good selectivity against 200 ppm glucose interference. This open-source solution significantly reduces the cost of spectrophotometric analysis while improving accessibility in educational and remote laboratories. The practical implication of this study is it has strong potential for use in educational settings and field-based protein quantification due to its low cost, portability, and adequate performance.

Indonesian Journal of ChemistryVol. 25(6)
Jenderal Soedirman University (ID)
Jenderal Soedirman University
Openalex Percentile: Top 63%
Biosensors and Analytical Detection
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Accessible Protein Quantification with a Low-Cost Spectrophotometer Using Bradford Reagent — Mekar Dwi Anggraeni, Hartiwi Diastuti, et al. · Indonesian Journal of Chemistry (2025) | TGRS Research Map | TGRS