Analytical and Mechanical Study of Transtibial Osseo-Integrated Prostheses Implant

In amputation surgery, osseointegration is the placement of a metal implant in the residual bone and is conducted with an external prosthesis. In this study, the prospective application of Ti–13Nb–13Zr alloy in a transtibial osseointegrated prosthesis was carefully examined. The alloy demonstrated favourable mechanical properties, such as strong mechanical strength with an average yield strength of 482 MPa, ultimate tensile strength of 551.843 MPa and modulus of elasticity of 74 GPa. In compression testing, the material showed its resilience to compressive loads, exhibiting 700 MPa yield strength and 1010 MPa compressive strength. The elastic modulus of Ti–13Nb–13Zr alloy is approximately 55–65 GPa, which is much closer to that of human bone (10–30 GPa) compared with that of Ti–6Al–4V alloy (110 GPa). This proximity reduces stress shielding, a common issue in implants that a mismatch in stiffness between the implant and bone leads to bone resorption. Analyses using the finite element method demonstrated uniform stress distribution, safety factors and minimal deformation for a range of implant sizes, guaranteeing structural integrity and functionality. The maximal von Mises stress on the tibia bone and implant did not surpass the yield tensile stress of the titanium alloy and bone, which is 470 and 175 MPa, respectively; the maximum safety factor at L=120 and D=3 and the stress levels are not expected to induce material failure. These findings bring up new possibilities for enhanced prosthetic design and use in the field of biomedical engineering by demonstrating the alloy’s potential suitability for osseointegrated prosthetic applications.

Authors

Institutions

Publication Details

Journal
Al-Khwarizmi Engineering Journal
Published
2025-12-01
DOI
https://doi.org/10.22153/kej.2025.09.005
Primary Topic
Orthopaedic implants and arthroplasty
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Analytical and Mechanical Study of Transtibial Osseo-Integrated Prostheses Implant

Jumaa S. Chiad, Ayad M. Takhakh, Saif M. Abbas, Kadhim K. Resan et al.
Al-Khwarizmi Engineering Journal
Orthopaedic implants and arthroplasty
article

Analytical and Mechanical Study of Transtibial Osseo-Integrated Prostheses Implant

Jumaa S. Chiad, Ayad M. Takhakh, Saif M. Abbas, Kadhim K. Resan, A. Yousef Saad, Abdullah Fatlawi
article en

Abstract

In amputation surgery, osseointegration is the placement of a metal implant in the residual bone and is conducted with an external prosthesis. In this study, the prospective application of Ti–13Nb–13Zr alloy in a transtibial osseointegrated prosthesis was carefully examined. The alloy demonstrated favourable mechanical properties, such as strong mechanical strength with an average yield strength of 482 MPa, ultimate tensile strength of 551.843 MPa and modulus of elasticity of 74 GPa. In compression testing, the material showed its resilience to compressive loads, exhibiting 700 MPa yield strength and 1010 MPa compressive strength. The elastic modulus of Ti–13Nb–13Zr alloy is approximately 55–65 GPa, which is much closer to that of human bone (10–30 GPa) compared with that of Ti–6Al–4V alloy (110 GPa). This proximity reduces stress shielding, a common issue in implants that a mismatch in stiffness between the implant and bone leads to bone resorption. Analyses using the finite element method demonstrated uniform stress distribution, safety factors and minimal deformation for a range of implant sizes, guaranteeing structural integrity and functionality. The maximal von Mises stress on the tibia bone and implant did not surpass the yield tensile stress of the titanium alloy and bone, which is 470 and 175 MPa, respectively; the maximum safety factor at L=120 and D=3 and the stress levels are not expected to induce material failure. These findings bring up new possibilities for enhanced prosthetic design and use in the field of biomedical engineering by demonstrating the alloy’s potential suitability for osseointegrated prosthetic applications.

Al-Khwarizmi Engineering JournalVol. 21(4)
Mustansiriyah University (IQ), American Orthotic and Prosthetic Association (US), Nahrain University (IQ)
Openalex Percentile: Top 43%
Orthopaedic implants and arthroplasty
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.