Electrochemical Biosensor for Homocysteine Detection Using Poly‐L‐Lysine Coated Reduced Graphene Oxide Nanocomposite

ABSTRACT Homocysteine (Hcy) plays a critical role in cellular metabolism. Elevated levels of Hcy are associated with various pathophysiological conditions such as atherosclerosis, myocardial infarction, thrombosis, and neurodegenerative disorders. In this research, a highly sensitive and selective biosensor was developed for Hcy detection using reduced graphene oxide (rGO), thionine (Thi), gold nanoparticle (AuNP), and poly‐L‐lysine (PLL) electrodeposited on indium tin oxide (ITO) electrode. The prepared sensor was highly sensitive with a limit of detection 3.3 µM and a linear detection range from 10 to 60 µM. The sensor was highly specific and selective for Hcy in the presence of interferents and in human serum samples. The sensor was found to be reproducible with multiple electrodes and showed stability for a week. Developed nanofabricated rGO/AuNP/Thi/ITO platform can be further explored for detection of various clinical biomarkers.

Authors

Institutions

Publication Details

Journal
ChemistrySelect
Published
2025-11-30
DOI
https://doi.org/10.1002/slct.202504155
Primary Topic
Folate and B Vitamins Research
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Electrochemical Biosensor for Homocysteine Detection Using Poly‐L‐Lysine Coated Reduced Graphene Oxide Nanocomposite

Sunil Kumar Singh, Ashish Kumar Maurya, Monika Sahu, Sunil Mittal et al.
ChemistrySelect
Folate and B Vitamins Research
article

Electrochemical Biosensor for Homocysteine Detection Using Poly‐L‐Lysine Coated Reduced Graphene Oxide Nanocomposite

Sunil Kumar Singh, Ashish Kumar Maurya, Monika Sahu, Sunil Mittal, Abhishek Panigrahi, Nisha Yadav, Pooja Yadav, Jyoti Singh
article en

Abstract

ABSTRACT Homocysteine (Hcy) plays a critical role in cellular metabolism. Elevated levels of Hcy are associated with various pathophysiological conditions such as atherosclerosis, myocardial infarction, thrombosis, and neurodegenerative disorders. In this research, a highly sensitive and selective biosensor was developed for Hcy detection using reduced graphene oxide (rGO), thionine (Thi), gold nanoparticle (AuNP), and poly‐L‐lysine (PLL) electrodeposited on indium tin oxide (ITO) electrode. The prepared sensor was highly sensitive with a limit of detection 3.3 µM and a linear detection range from 10 to 60 µM. The sensor was highly specific and selective for Hcy in the presence of interferents and in human serum samples. The sensor was found to be reproducible with multiple electrodes and showed stability for a week. Developed nanofabricated rGO/AuNP/Thi/ITO platform can be further explored for detection of various clinical biomarkers.

ChemistrySelectVol. 10(45)
Central University of Punjab (IN)
Openalex Percentile: Top 47%
Folate and B Vitamins Research
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.