Electromyographic background noise in thyroid surgery: causes, characteristics, and mitigation strategies

Accuracy of intraoperative neuromonitoring (IONM) largely depends on the quality of electromyography (EMG) signals, which are frequently affected by background noise. EMG background noise during thyroid surgery is related to various factors including electrical interference, electrode malposition, residual neuromuscular blockade, fluid conduction, and motion artifacts. Electrical interference from electrocautery and unstable grounding, as well as poor electrode contact, were identified as the most frequent causes of background noise. Skin electrodes exhibited relatively higher baseline noise levels compared to EMG tubes or needle electrodes. Implementation of impedance monitoring, shielded cables, adaptive filters, and machine learning–based artifact classification can effectively improve the signal-to-noise ratio and diagnostic reliability of IONM. Reducing EMG background noise is critical to ensure accurate neural monitoring during thyroid surgery. Optimized threshold calibration, stable electrode fixation, and standardized intraoperative protocols are essential to minimize noise-related diagnostic errors. Future research should focus on automated noise recognition algorithms and improved electrode designs to further enhance monitoring reliability and surgical safety.

Authors

Publication Details

Journal
Korean Intraoperative Neuromonitoring Society
Published
2025-11-30
DOI
https://doi.org/10.54441/jnn.2025.5.2.184
Primary Topic
Thyroid and Parathyroid Surgery
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Electromyographic background noise in thyroid surgery: causes, characteristics, and mitigation strategies

Sung‐Chan Shin
Korean Intraoperative Neuromonitoring Society
Thyroid and Parathyroid Surgery
article

Electromyographic background noise in thyroid surgery: causes, characteristics, and mitigation strategies

Sung‐Chan Shin
article en

Abstract

Accuracy of intraoperative neuromonitoring (IONM) largely depends on the quality of electromyography (EMG) signals, which are frequently affected by background noise. EMG background noise during thyroid surgery is related to various factors including electrical interference, electrode malposition, residual neuromuscular blockade, fluid conduction, and motion artifacts. Electrical interference from electrocautery and unstable grounding, as well as poor electrode contact, were identified as the most frequent causes of background noise. Skin electrodes exhibited relatively higher baseline noise levels compared to EMG tubes or needle electrodes. Implementation of impedance monitoring, shielded cables, adaptive filters, and machine learning–based artifact classification can effectively improve the signal-to-noise ratio and diagnostic reliability of IONM. Reducing EMG background noise is critical to ensure accurate neural monitoring during thyroid surgery. Optimized threshold calibration, stable electrode fixation, and standardized intraoperative protocols are essential to minimize noise-related diagnostic errors. Future research should focus on automated noise recognition algorithms and improved electrode designs to further enhance monitoring reliability and surgical safety.

Korean Intraoperative Neuromonitoring SocietyVol. 5(2)
Openalex Percentile: Top 43%
Thyroid and Parathyroid Surgery
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.